AirSpeed 1050 B3 Installation Guide
DUG01593
Airspan Commercial and Internal Use
16
2 Verifying Prerequisites
Prior to installing the AirSpeed 1050 B3, verify the required safety, power, tools, parts and
components. This chapter includes the hardware, software, and client requirements for installation.
Verify the availability of:
AirSpeed 1050 B3 unit
Mounting adaptor (ordered separately)
SFP / RJ45 connectors adaptors (ordered separately)
Desired location with available power source
2.1 Verify the Tools
Table 4. Tool Requirements - Mounting
Tool
Use
Large flat bladed screwdriver
securing the pole straps
13 mm wrench
for securing the M8 bolts
13 mm torque wrench
for final tightening of the M8 bolts
(Tighten to a torque of no more than 15 Nm (11
ft-lb) max.)
Knife
For cable preparation
Small side cutters
For power cable preparation
Wire strippers
For power cable preparation
2.2 Verify the Parts and Kits
Note:
Verify order and requirements to ensure the correct unit type is being installed.
Note:
Currently available - AS105-U03M1-B08A
Table 5: AirSpeed 1050 B3 Components
Installation Kit / Part
Product Code
AS P/N
Description
AirSpeed 1050 B3
B40 Fiber + copper
BH, AC power
AS105-U03M1-B08A
998-73-
033RK
AirSpeed 1050, 1825-1845MHz (B03),
Copper Backhaul, AC
Nut, M6, Full, SS, A2, DIN934 (x2)
Spring Lock Washer M6 SQ End SS
A2 DIN127B (x2)
HEX Head Screw M6x30mm, SS A2
DIN933 (x1)
Mounting Adaptor
AS105-U-PMADPT-1
402-00-841
Mounting Adaptor for TEPCO (ordered
separately)
External Plug
Connector Adapter
power
CON-ADP-OCT-PWR-1
300-50-135
Power AC - 3 position power(26mm pitch)
Screw Version & metal/plastic tie (Included)