Air4G Installation Guide
Page 58
Commercial in Confidence
UGD-D00229 Rev B
Table 26 - Cable hole sizes
Cable Entry hole determination
Gland hole PG11 (M18) for cable terminating at Air4G
Gland hole PG29 (M36) for cable 12AWG x6
Gland hole PG16 (M22) for cable 14AWG x2
Note:
Save the rubber grommets from the plugs to be used on the weatherproof
glands (connectors).
5. Remove the nut on the weatherproof connector and slide the rubber grommet onto the
threaded shaft.
6. Set the weatherproof connector into the hole and from inside the box, thread the included
nut onto the shaft until tight.
7. Insert the exposed wires into the relevant screw-type terminal block (
+
to
+
and
–
to
–
)
and then secure them in place by tightening the screw of each terminal.
8. Fasten the Junction box onto the pole or wall as required within the required distance of
the Air4G enclosure.
9. Perform the same procedure (steps 3-7) with the cable terminating in the in the Air4G
enclosure.
10. Open the connector clamp collar and feed about 101.6 mm (4 inches) of cable from the
Air4G through it and into the box. Tighten the collar around the cable, forcing the seal to
compress around the cable.
11. Replace the cover by using the four (4) screws, ensuring the gasket (for weatherproofing)
is firmly in place on the rim of the cover.
Note:
It is important to provide strain relief and drip loop for the cables. Create a
drip loop and strain relief using cable tie, to tie cable to pole, as displayed in the
figure below: