Air4G Installation Guide
Page 28
Commercial in Confidence
UGD-D00229 Rev B
Part
Description
Air4G
Air4Gp
Air4Gs
Image
Ext. Int.
30cm Surge to
BS Cable
For connecting the Surge protector
to the Base Station. (RF cable assy
TNC to TNC- RA,30cm,RG58
)
Protector
mounting
bracket
For mounting the Surge protector to
the BS.
X
Protector
mounting
bracket clamp
For clamping the bracket to the BS.
Includes necessary hardware.
X
X
X
Optional Cables
•
16m GPS Cable - RG58 TNC-TNC - For mounting remotely from the base station unit.
Should be used in conjunction with the Remote GPS Antenna Mounting Bracket - P/N
CBL-GPS-TNC-16-1
•
40m GPS
Shielded
Cable TNC-TNC for remote GPS mounting option. An optional
shielded cable for when excessive interference is detected, such as strong TV
transmission interference.– P/N CBL-GPS-TNC-40-1
Note:
For additional cable lengths contact your Airspan representative.
The Air4G power supply (PS) can be installed with various cable lengths according to the site
requirements. The cable lengths are determined by the length of the run between the PS and the
Air4G. Use the following table to determine the required power supply output to ensure proper
operation of the Air4G.
Table 12 - Input Power for Air4G
Air4G 2x10
(2.3-2.7 GHZ)
&
Air4G 0707
(698-746 MHz)
Air4G 3x05
(3.3-3.38 GHZ)
Air4G 5.x
Input Voltage to Air4G (1)
-36 VDC to -60 VDC
-36 VDC to -60 VDC
-36 VDC to -60 VDC
PS output Voltage – 30
meter cable (2)
-42 VDC min
-41 VDC min
-41 VDC min
PS output Voltage – 75
meter cable (2)
-50 VDC min
-46 VDC min
-45 VDC min
PS output Voltage – 100
meter cable (2)
-53 VDC min
-49 VDC min
-48 VDC min