TROUBLE CHECK
REMEDY
●
Power plug correctly connected
●
Connect plug correctly
●
POWER button
“
OFF
”
●
Press POWER button to
“
ON
”
●
Fuse (supply) blown
●
Replace fuse
●
Breaker on switch board
●
Check load capacity and reset
tripped
●
Ambient temp. too high
●
Use only below 113
℉,
45
℃
(over 113
℉,
45
℃
)
●
Filter blocked with dust
●
Clean Filter
●
Dust in heat exchanger
●
Clean heat exchanger
●
Obstacle against inlet side
●
Remove and allow 20" (51 cm) clearance
●
Ambient temp. too high
●
Use only below 113
℉,
45
℃
(over 113
℉,
45
℃
)
1. To remove filters, slide up a little
①
and pull
towards you
②
.
2. Clean the filters with water or compressed air.
3. Clean evaporator and condenser units with a
vacuum cleaner or compressed air.
1. After cleaning, completely dry
the inside of the unit by
operating on
‘
Fan Mode
’
for 3 to 4 hours.
2. Turn
“
OFF
”
at control panel,
remove plug from socket. Coil
and store cable neatly.
3. Keep machine suitably covered to
prevent damage by damp,
humidity and dust.
MAINTENANCE
CLEANING THE AIR FILTERS
MAINTENANCE
rev0-2011
Operating Instruction & Parts Manual
NOT
WORKING
POOR
COOLING
TROUBLESHOOTING CHART
Summary of Contents for HSCO-14
Page 16: ...rev0 2011 Operating Instruction Parts Manual...
Page 18: ...rev0 2011 Operating Instruction Parts Manual MEMO...
Page 19: ...rev0 2011 Operating Instruction Parts Manual MEMO...
Page 23: ...rev0 2011 Manuel d utilisation et manuel des pieces SCH MA DE C BLAGE HSCO 14 18 HSCO 24A...
Page 38: ...rev0 2011 Manuel d utilisation et manuel des pieces MEMO...
Page 39: ...rev0 2011 Operating Instruction Parts Manual MEMO...
Page 43: ...rev0 2011 Manual de Operaci n y Manual de Partes DIAGRAMA DE CABLEADO HSCO 14 18 HSCO 24A...
Page 58: ...rev0 2011 Manual de Operaci n y Manual de Partes MEMO...