3.3 Checking Current Output
The following table is a direct reference to FAA AC 150/5345-10H Section 3.3.1.1, Table 1. Once
your CCR is installed, set up, and operational, you may choose to verify the measured output
current with a digital multimeter (DMM) and current clamp.
Maximum
Output
Current
Total
Step
Count
Step
Nominal
Output
Current
Allowable
Current
Range
Measured
Current
Displayed
Current
6.6
3
B10
4.8
4.7
–
4.9
B30
5.5
5.4
–
5.6
B100
6.6
6.5
–
6.7
6.6
5
B1
2.8
2.7
–
2.9
B2
3.4
3.3
–
3.5
B3
4.1
4.0
–
4.2
B4
5.2
5.1
–
5.3
B5
6.6
6.5
–
6.7
Table 2: CCR Output Currents