background image

 

  11 | Page 

Installation Overview 

The CID 75k mounts to a wall utilizing a small two-piece Vesa mount (provided). 
The mount comes preinstalled on the CID 75k. To install the wall mount section of 
the Vesa mount, you must first remove the wall mount section from the back of 
the unit. This is done be separating the two halves of the mount. To separate the 
two halves, you must first remove the two Phillips screws located on the bottom of 
the bracket. 
  

The mounting kit contains: 

1.

 

Wall Mount Bracket (already attached to the unit). 

2.

 

Four enclosure Threaded Anchors 

3.

 

Four Phillips Screws 

 

 

 

CID 75k 

Wall Mount 
Bracket 

Wall 

Threaded Anchors 

Summary of Contents for CID 75k

Page 1: ...1 Page AIRPHX CID 75k User Installation Guide Rev 1 7 February 22 2021...

Page 2: ...C power cord o CID 75k Quick Reference Guide o AIRPHX 7 Day Timer User Guide o Annual supply of filters o Welcome card o Complete Indoor Disinfection decal Choose a central mounting location that has...

Page 3: ...s that can cause the CID 75k to go into standby 8 6 Operations Controls 9 On Off Switch 9 Active Indicator 9 7 Day Timer Switch 9 Filter Indicator Switch 9 Filter Note 9 7 Operations Controls cont 10...

Page 4: ...et Procedure 16 Filter Location 16 14 Filter Replacement and Reset Procedure cont 17 15 Filter Replacement and Reset Procedure cont 18 16 Plasma Chamber Replacement and Reset Procedure 19 17 Plasma Ch...

Page 5: ...location for the CID 75k within the treatment area o Avoid locations with high humidity like swimming pools whirlpools and showers High moisture levels can damage the CID 75k s plasma chamber o Mount...

Page 6: ...epairs to the CID 75k must be performed by qualified service personnel Please contact your AIRPHX representative with any service request Do not open the CID 75k for any reason Doing so may put you at...

Page 7: ...F position and its LED is not illuminated 7 Day Timer Mode In this mode of operation the CID 75k will be controlled by the schedule that has been programmed into the 7 Day Timer The 7 Day Timer mode i...

Page 8: ...lacement and Reset Procedure for more details 2 The unit has been in operation for a year and it is time to replace the plasma chamber In this situation the Service LED will illuminate red indicating...

Page 9: ...n of the CID 75k is controlled by schedules programmed into the 7 Day Timer During an off schedule program the unit will go into standby awaiting an on schedule program to resume and the Active LED wi...

Page 10: ...on the unit s LCD display location on the front of the unit Some faults can be reset after they have been cleared by pressing the Fault Indicator button Example of clearing a fault Removing the plasm...

Page 11: ...st first remove the wall mount section from the back of the unit This is done be separating the two halves of the mount To separate the two halves you must first remove the two Phillips screws located...

Page 12: ...lips Screws Recommended tools Level Pencil Long Phillips Screwdriver Punch or Scratch Awl Drilling Threaded Drywall Anchor Phillips Screw Wall Mount Section Phillips Locking Screws Top of Mount CID 75...

Page 13: ...rewdriver It may be easier to start the anchor if you make a small hole first using a Scratch Awl 6 Screw the anchors in all the way until the outer rim of the anchor is flush with the drywall 7 Using...

Page 14: ...14 Page 11 Installation Procedure Fig 1 Fig 1 Wall Mount Locking Screws...

Page 15: ...15 Page 12 Installation Procedure Fig 2 Wall Fig 2 Top Wall Section of the Vesa Mount Threaded Anchors CID 75k Section of the Vesa Mount...

Page 16: ...the light If light can easily be seen through the filter it can be used for another 30 days 5 Replace grill by carefully hinging on to the bottom of the housing first and snapping it into place on the...

Page 17: ...17 Page 14 Filter Replacement and Reset Procedure cont Fig 1A...

Page 18: ...18 Page 15 Filter Replacement and Reset Procedure cont Fig 1B...

Page 19: ...river loosen and remove all four screws that secure the exhaust grill in place as shown in Fig 1D 5 The end of the plasma chamber tube will be exposed once the grill is removed Grasp the end of the tu...

Page 20: ...20 Page 17 Plasma Chamber Replacement Process cont Plasma Chamber Exhaust Grill Fig 1C Fig 1D Exhaust Grill Screws...

Page 21: ...21 Page 18 Plasma Chamber Replacement Process cont Fig 1E Plasma Chamber Contacts...

Page 22: ...22 Page 19 Plasma Chamber Replacement Process cont Fig 1F Tab...

Page 23: ...red on press the Fault Indicator to reset the display mode Q What should I do if the Active Indicator is illuminated RED A Check the LCD on the front of the unit This will display the issue with the u...

Page 24: ...ere is the CID 75k manufactured A The CID 75k is manufactured at two locations 1 The AIRPHX Technical Operations Center in Cary NC It is an EPA registered establishment No 94099 NC 1 and 2 Nu Way Indu...

Page 25: ...AND PROPERLY NOTIFY AIRPHX IN WRITING OR BY FAX WILL RESULT IN NULLIFICATION OF THIS WARRANTY ANY PARTS REPAIRS MODIFICATION AND OR MAINTENANCE SUPPLIED BY A NON AIRPHX REPRESENTATIVE OTHER THAN AIRPH...

Page 26: ...irs performed on AIRPHX equipment missing a serial number or with a serial tag that has been altered or defaced 3 Service calls to correct installation of the equipment or instruct the owners on how t...

Page 27: ...XPRESS WARRANTY SET FORTH ABOVE FAILS IN ITS ESSENTIAL PURPOSE Exclusive Remedies For any product described above that fails to conform to its warranty an AIRPHX representative will exclusively provid...