16 Plasma Chamber Replacement and Reset Procedure
1.
Turn the power switch off on the CID 75k.
2.
Carefully remove the replacement plasma chamber from the box it was shipped
in.
Note: The plasma chamber contains a glass element and is very fragile. If the
shipping box or plasma chamber looks damaged, please contact your AIRPHX
representative for a replacement.
3.
The plasma chamber is located behind the exhaust grill located on the right side
of the unit. This grill must be removed to gain access to the plasma chamber as
shown in Fig 1C.
4.
Using a Phillips screwdriver, loosen and remove all four screws that secure the
exhaust grill in place as shown in Fig 1D.
5.
The end of the plasma chamber (tube) will be exposed once the grill is
removed. Grasp the end of the tube and pull it straight out of the unit.
6.
With the new plasma chamber in hand, align the contacts on the plasma
chamber with the two notches in the enclosure, making certain that the label
on the plasma chamber is facing towards you as shown in Fig 1E.
7.
Keep the plasma chamber in a straight orientation as you slide it into the unit.
You will feel the plasma chamber come to a stop once it is in its contact socket.
Push the plasma chamber in until fully seated.
8.
Replace the exhaust grill taking note of the alignment of the tab on the grill
itself as shown in Fig 1F.
Summary of Contents for CID 75k
Page 1: ...1 Page AIRPHX CID 75k User Installation Guide Rev 1 7 February 22 2021...
Page 14: ...14 Page 11 Installation Procedure Fig 1 Fig 1 Wall Mount Locking Screws...
Page 17: ...17 Page 14 Filter Replacement and Reset Procedure cont Fig 1A...
Page 18: ...18 Page 15 Filter Replacement and Reset Procedure cont Fig 1B...
Page 21: ...21 Page 18 Plasma Chamber Replacement Process cont Fig 1E Plasma Chamber Contacts...
Page 22: ...22 Page 19 Plasma Chamber Replacement Process cont Fig 1F Tab...