10
NORMAL
In Normal mode the room temperature
is maintained to the user set
temperature setpoint.
TIMER
In Timer mode weekly timers determine
when is Timer temperature setpoint
used instead of normal setpoint. The
Timer temperature setpoint is set for
each room/zone and is repeated every
week. Each room/zone has 4x7=28 ON/
OFF weekly timers. 4 different ON/OFF
cycles can be set for each weekday.
ECO
In ECO mode the regulation maintains
a different temperature setpoint
that the user can change, called ECO
setpoint. ECO mode is set for all rooms/
zones, however the ECO temperature
setpoint is set for each room/zone
separately.
ECO mode is not set for rooms/zones
that have “MIN” mode active. “MIN”
mode means that heating is off in that
room, therefore ECO mode in that room
should not be activated.
MIN
In MIN operating mode temperature
regulation will not allow temperature
drop below +5°C. This mode is used also
on times when heating is not required,
while still preventing frost protection.
In addition the actuator valves will be
opened and closed briefly in every 84h
to prevent them getting stuck.
OPERATING MODES
Summary of Contents for RoomUnit
Page 15: ...15 RoomUnit BRUKSANVISNING NORSK MED ELLER UTEN INFRAR D GULVSENSOR...
Page 29: ...29 RoomUnit ANV NDARMANUAL SVENSK MED OCH UTAN INFRAR D GOLVSENSOR...
Page 34: ...34 VERSIKT Batterih llare 3 x AAA batterier Parkopplingsknapp IR golvsensor Serienummeretikett...
Page 43: ...43 RoomUnit K YTT OHJE SUOMI LATTIAN INFRAPUNA AN TURILLA JA ILMAN LATTIAN INFRAPUNA ANTURIA...
Page 57: ...57 RoomUnit BRUGERVEJLEDNING DANSK MED OG UDEN INFRAR D GULVF LER...
Page 71: ...71 RoomUnit KASUTUSJUHEND EESTI INFRAPUNA P RANDAANDURIGA JA ILMA...
Page 85: ...85 RoomUnit BENUTZERHANDBUCH DEUTSCH MIT ODER OHNE INFRAROT FUSSBODEN SENSOR...
Page 99: ...99 RoomUnit MANUEL DE L UTILISATEUR FRAN AIS AVEC ET SANS CAPTEUR INFRAROUGE...
Page 113: ...113 RoomUnit MANUAL DE USUARIO ESPA OL CON Y SIN SENSOR DE PISO INFRARROJO...
Page 127: ...127 RoomUnit...
Page 128: ...128 AirPatrol SmartHeat SmartHeat 868 www airpatrol eu support AirPatrol SmartHeat...
Page 130: ...130 1 LED 10 2 3 SET ZONE PAIRING ERROR 4 5 6 ECO MIN 7 8...
Page 131: ...131 5 5 1 6 7 8 2 3 4 5...
Page 132: ...132 3...
Page 133: ...133...
Page 134: ...134 SmartHeat 1 2 PAIR LED 3 PAIR LED...
Page 135: ...135 4 LED SELECT LED LED 5 PAIR LED 3 5 PAIR LED 6 5...
Page 136: ...136 4 8 28 4 ECO ECO ECO ECO ECO MIN MIN ECO MIN MIN 5 84...
Page 137: ...137 20 1...
Page 140: ...140 www airpatrol eu smartheat app RoomUnit App Web MIN ECO MIN 5 C...