AB1600_V0.3
Burst Data Receiving
Figure 4-6 Burst Data Receiving setting of Rx Tab
receiving. In order to measure BER, a signal generator is required to generate Bluetooth standard packets
and transmitted to the DUT. The associated settings of the signal generator must be set as follows,
BD address = 0x006BC6967E
LT_ADDR = 7
Payload data = PN9 with initial seed = 0x01FF
If the transmitted data of signal generator is successfully received and decoded by DUT, a group of
BER test results will be shown in the output window including: (as in figure 4-6)
BER(%): Bit error rate
Bits:
Number of received data bits
#RPkt:
Number of received packets
#EPkt:
Number of expected packets
#ACloss: Number of packets with AC_Loss
#Hdr:
Number of packets with header error
#CRC:
Number of packets with CRC error
RSSI:
Received Signal Strength Indication