![Airmux Airmux-200 Installation And Operation Manual Download Page 12](http://html1.mh-extra.com/html/airmux/airmux-200/airmux-200_installation-and-operation-manual_2878541012.webp)
Quick Start Guide
AirMux-200
Installation and Operation Manual
2
Installing AirMux-200 Units
5. Connect the RJ-45 connectors to both ends of the cable, use the pinout table and
diagram below:
IDU RJ-45
Wire Color
Function
ODU RJ-45
1
White/Green
Ethernet (RxN)
1
2
Green
Ethernet (RxT)
2
3
White/Orange
Ethernet (TxT)
3
4
Blue
Power (+)
4
5
White\Blue
Power (+)
5
6
Orange
Ethernet (TxN)
6
7 White/Brown
Power (
−
)
7
8 Brown Power (
−
)
8
6. Secure the ODU and ground cables to the mast or brackets using cable ties.
7. Repeat the procedure at site B.
To align the ODU:
1. Connect power to the site A IDU.
After approximately 20 seconds the ODU beeper starts beeping, this is
normal.
2. Verify normal operation of the IDU by the LED indications on the front panel.
Indicator Color Status
PWR Green
ON
IDU Orange
Green
Blinks for 40 seconds during startup
Blinking slowly shows normal operation
ODU
Green
Blinking slowly shows normal operation
AIR I/F
Orange
Green
Blinks for short duration during installation
Blinking slowly shows normal operation
SERVICE
Green
Blinking slowly shows normal operation
OFF when Service selected is Ethernet only