4. Troubleshooting
4-10
4.2.11
Even when the pressure at consumer’s side drops, it will not recover from
purge control operation
Service pressure and
output voltage
will not meet
Wire
disconnected
Purge releasing pressure
too low
86psi(0.6MPa)[6.0bar]
Adjust (See 1.6.2)
Check output voltage of
service pressure sensor
(See 3.12)
Output voltage normal
Replace it
Not wire disconnected
Repair wire connection
Repair or replace it
Faulty setting of purge
releasing pressure (L)
Trouble of service pressure
sensor
Trouble of emergency
controller
Check setting of purge
releasing pressure (L)
Check wire connection
between service pressure
sensor and emergency
controller
Disconnection or faulty
contact between emergency
controller and service
pressure sensor