WARNINGS AND SAFETY CONSIDERATIONS

General

This installation and service guide contains important instructions and safety information for the AirMaid® Ozone 

Generator (hereafter referred to as ”The Generator”).  Read this guide fully before attempting to install, operate, or 

perform maintenance on The Generator. 

The Generator is for commercial use and intended for the treatment of air extracted from the exhaust ducts of new 

or existing commercial kitchens and building ventilation systems that exhaust to the outdoors. The completed 

installation must meet all local, state and national building, electric and fire safety codes.

A typical installation into a commercial kitchen exhaust duct is described. Other applications for treating extraction air 

may also be possible, but only for air which is released into the outside environment and never into working or living 

spaces. In all cases, the specific requirements according to this guide must be fulfilled.  

The device may not be used by children or by persons with diminished physical, sensory or mental capacity or lack 

of experience and knowledge unless supervised or having received instruction. Supervise children to ensure that 

they do not play with the device.

Always disconnect the electric power source from The Generator before performing any service or maintenance.

The Generator, alarm panel and connections to inlet air and extraction ducts must be installed by qualified per-

sonnel, in compliance with all manufacturer instructions as well as local, state and national building,  

electric and fire safety codes.

Troubleshooting & Requesting Service 

In the event of operational difficulties with The Generator please contact your distributor or Interzon Technical 

Support.  

Repairs must only be performed by Interzon-trained and authorized service personnel unless prior written consent 

has been given. Only original repair parts provided by the manufacturer may be used when servicing The Generator.

If damage has occurred during shipping, notify the freight carrier at once so that a claim can be filed with the carrier.

This equipment is heavy! See product specifications for rated weight. Always exercise extreme caution 

when mounting or dismounting The Generator to assure it cannot be dropped. Use only approved work 

platforms to access The Generator. Never stand on cooking equipment as falls can result in serious inju-

ries. Wear industry-prescribed work clothing, gloves and eye protection while mounting, dismounting or 

servicing The Generator.  

Electrical Shock Hazard! Disconnect power before servicing. Replace all parts and panels before operating. 

Failure to do so can result in electrical shock, burns or death.

 This unit emits low levels of ozone into the exhaust duct. If improperly used by unqualified personnel 

extended exposure to ozone can result in irritation to eyes, skin and lungs. Always observe industry guide-

lines and safety precautions when working with equipment that generates ozone.

Summary of Contents for 10000V

Page 1: ...stallation Operation and Maintenance AirMaid V Series Ozone Cleaning System NORTH AMERICAN 120 VAC 2000V 5000V 10000V 20000V AirMaid ozone cleaning system Innovative Air Treatment Revised February 14...

Page 2: ...2...

Page 3: ...and extraction ducts must be installed by qualified per sonnel in compliance with all manufacturer instructions as well as local state and national building electric and fire safety codes Troubleshoo...

Page 4: ...generator 4 If the regular inspection and cleaning maintenance for the product are not followed 5 Any other damage resulting from accident alteration misuse if the serial number is removed or defaced...

Page 5: ...EU3 shall be in stalled Filter box inlet air can be taken from above an inner ceiling from an adjoining space or from the outdoors with precautions taken to prevent the entry of moisture If taken fro...

Page 6: ...e point of exhaust With this in mind we recommend a minimum dwell time of 2 seconds to obtain good results for the reduction of cooking odor However please keep in mind that a longer dwell time will o...

Page 7: ...THIS TYPICAL INSTALLATION DETAIL IS FOR REFERENCE ONLY THE PROJECT SPECIFIC INSTALLATION MUST MEET ALL LOCAL STATE AND NATIONAL BUILDING ELE CTRIC AND FIRE SAFETY CODES LAYOUT SHOWN IS COMPLIANT WITH...

Page 8: ...nlet and outlet pipes Multiple duct connections are unnecessary As long as you have sufficient static pressure to obtain the correct bleed airflow through the generator then multiple connections to th...

Page 9: ...ownward Never screw or drill through the generator Hang using 5 16 in threaded rods and anchor these with nuts on each side of the respective bracket 2 Fasten the outlet pipe 6 between the ozone gener...

Page 10: ...eir own alarm panel Electrical Connection The installation must be performed by an authorized electrician and follow national standards and regulations The fan interlock displayed on the diagram below...

Page 11: ...if you choose not to accept their factory defaults ALARM DELAY 5 minutes INSP CLEAN 12 months 4 Perform Functional Check Of CGC Cell s 4 1 Ensure the ventilation system of the facility is running norm...

Page 12: ...on with Interzon 7 1 Register the generator online within 10 days installation at www interzon com Registering the AirMaid generator installation is important to both the reseller and end customer Fir...

Page 13: ...em with the static pressure Kitchen hood filters might not be installed properly or a fire damper or control damper if installed is not open Perform troubleshooting following the flow chart in section...

Page 14: ...the delay is set to 5 minutes in order to prevent an alarm in case of a temporary disruption SET INSP CLEAN Service and maintenance interval in months After this time period the alarm panel will blin...

Page 15: ...if cleaning is performed before the timed reminder is displayed 1 Number of registered events 2 Cause A Alarm C Calibration P Pressure Fault N Not Connected generator not detected 3 Event Duration 4...

Page 16: ...the glass electrodes of the ozone cells are not damaged or cracked A proper ozone cell should be clean and free from any mechanical damage according to the picture to the right above Caution The glas...

Page 17: ...ired negative pressure is established The thermal switch prevents the ozone generator from overheating The main switch is supplied with a thermal overload protection of 4A Facts about Ozone Ozone is a...

Page 18: ...or Troubleshooting completed Turn off the main power switch and remove the service hatch on the bottom of the generator Are all electrodes of the CGC Cell s free from damage Please perform the steps i...

Page 19: ...one E mail Product Identification Model AirMaid 2000V AirMaid 5000V AirMaid 10000V AirMaid 20000V Product Serial No Date of installation mm dd yyyy From Commissioning Generator Airflow cfm Generator P...

Page 20: ...6 8 544 444 39 SE 183 62 T by Stockholm E mail info interzon com Sweden Internet www interzon com Reproduction modification or translation without a prior written consent is forbidden with the excepti...

Reviews: