background image

14

TECHNICAL CHARACTERISTIC TABLES

The manufacturing firm refuses all responsibility for any possible imprecision in this booklet, due 

to misprints or clerical errors. It reserves the right to make all the changes that it will consider 

necessary in its own products, without effecting the essential characteristics of functionality and 

safety

.

This product complies with EU Directive 2002/96/EC. 

The crossed-out dustbin symbol reported on the appliance indicates that the appliance 

must be disposed of separately from other domestic refuse at the end of its useful life. 

It must therefore be delivered to a waste recycling centre specifically for electric and 

electronic equipment or returned to the retailer at the moment of purchase of a new 

equivalent appliance.

The user is responsible for delivering the appliance to the appropriate collection centre at the end of its 

useful life, Failure to do so may result in a fine, as provided for by laws governing waste disposal. 

Differential collection of waste products for eventual recycling, treatment and environmentally friendly 

disposal helps reduce possible negative effects on the environment and health, and also enables the 

materials making up the product to be recycled.

For more detailed information on the available refuse collection systems, refer to the local Municipal Solid 

Waste disposal centre or the shop where the product was purchased.

Producers and importers are responsible for fulfilling their obligations as regards recycling, treatment and 

environmentally friendly disposal by directly or indirectly participating in the collection system.

Short title or reference to the measurement and calculation methods used to establish compliance 

with the above requirements.

The performance of each individual burner is calculated according to standard EN 30-2-1 + A1:2003 + 

A2:2005

The total efficiency of the hob is calculated according to the EU Regulation 66/2014 Par. 2.2

The efficiency is calculated only for the burners with a nominal capacity exceeding 1,16 KW (  EN 30-2-1 

+ A1:2003 + A2:2005; Par. 4.1)

Information which is relevant to the customer to minimize the energy consumption during usage:

Energy Saving Tips: use pots having flat base, Use pots with proper size, use pots with lid, minimize the 

amount of liquid or fat, when liquid starts boiling reduce the setting.

BURNERS

GAS

NORMAL 

PRESSURE

NORMAL 

RATE

I N J E C T O R 

DIAMETER

TAPE BY 

PASS 

DIAMETER

NOMINAL HEAT 

INPUT (W)

EE 

gas 

burner

DESCRIPTIONS

mbar

g/h

L/h

1/100 mm

1/100 mm

Max.

Min.

(%) *

2

SEMI-RAPID

G30 / G31

28 - 30 / 37

126

-

65

31

1750

600

57

G20

20

-

165

97

Reg.

1750

600

3

AUXILIARY

G30 / G31

28 - 30 / 37

71

-

50

27

1000

450

/

G20

20

-

99

72

Reg.

1000

450

4

TRIPLE CROWN

G30 / G31

28 - 30 / 37

277

-

95

60

3800

2100

58.1

G20

20

-

362

142

Reg.

3800

2100

Summary of Contents for AT635HIX

Page 1: ......

Page 2: ......

Page 3: ...pparecchio Sorvegliare i bambini per tutto il tempo di funzionamento dell apparecchio badando che non stiano nelle vicinanze e che non tocchino le superfici non ancora completamente raffreddate Prima...

Page 4: ...le di massimo e quella di minimo mai tra la posizione di massimo e il punto di chiusura Per interrompere l alimentazione gas ruotare la manopola in senso orario sulla posizione di chiusura In mancanza...

Page 5: ...i aggressivi Si consiglia di lavare con acqua saponata e asciugare con panno morbido La lucentezza viene mantenuta mediante l uso periodico di prodotti chimici idonei reperibili in commercio Bruciator...

Page 6: ...l forno Inoltre n e l c a s o d i installazione sopra un forno senza ventilazione forzata di raffreddamento per consentire u n a d e g u a t a a e r a z i o n e dovranno essere p r e v i s t e d e l l...

Page 7: ...ttrico sia munito di un efficace collegamento di terra secondo le norme e le disposizioni di legge La messa a terra obbligatoria Se l apparecchio sprovvisto di spina applicare al cavo di alimentazione...

Page 8: ...i sezione 3 x 0 75 mm2 Il collegamento alla morsettiera va eseguito come illustrato in fig 10 10 A cavetto L marrone fase cavetto N blu neutro cavetto verde giallo terra ISTRUZIONI PER L INSTALLATORE...

Page 9: ...costruttrice declina ogni responsabilit per possibili inesattezze imputabili ad errori di stampa o di trascrizione contenute nel presente libretto Si riserva il diritto di apportare ai propri prodotti...

Page 10: ...not play with the appliance While the appliance is running watch the children and make sure they neither stay near the equipment nor touch the surfaces that have not cooled down completely Before powe...

Page 11: ...with matches setting the knob to the start up point large flame fig 1 BURNERS Power W of pots Auxiliary 1000 10 14 cm Semi rapid 1750 16 18 cm Triple crown 3800 24 26 cm Notice When the equipment is...

Page 12: ...the hob is going to be installed on the top of a built in oven w i t h o u t f o r c e d cooling ventilation proper air vents must be installed to guarantee an adequate ventilation with the lower air...

Page 13: ...the label under the appliance Make sure that the electric system is provided with an effective ground connction in compliance with the regulations and provisions of the law Grounding is compulsory If...

Page 14: ...er supply cable If the power supply cable should be replaced it is necessary to use a cable with a section of 3x0 75mm2 type H05VV F or H05RR F complying with the regulations in force The connection t...

Page 15: ...refuse collection systems refer to the local Municipal Solid Waste disposal centre or the shop where the product was purchased Producers and importers are responsible for fulfilling their obligations...

Page 16: ...t et qu ils ne touchent pas les surfaces qui n ont pas encore compl tement refroid Surveiller les enfants pendant le fonctionnement de l appareil et veiller ce qu ils ne restent pas proximit et qu ils...

Page 17: ...e point d allumage grande flamme fig 1 Br leurs Puissance W Casseroles Auxiliaire 1000 10 14 cm Semi rapide 1750 16 18 cm Triple couronne 3800 24 26 cm Avertissements Contr ler toujours que les bouton...

Page 18: ...gtemps en contact avec de l eau calcaire ou des d tergents agressifs Il est conseill de laver avec de l eau savonneuse et de s cher avec un chiffon doux Le brillant se garde en utilisant p riodiquemen...

Page 19: ...ig 4 En cas d encastrement sur une base avec four il faudra s assurer que l installation r ponde aux normes de s curit en vigueur I faudra en particulier veiller ce que le c ble lectrique et le tuyau...

Page 20: ...ectrique doit correspondre celle indiqu e sur l tiquette situ e sous l appareil V rifier que l installation est quip e d un branchement la terre efficace conform ment aux normes et aux dispositions de...

Page 21: ...acement c ble d alimentation En cas de remplacement du c ble d alimentation il faut utiliser un c ble conforme aux normes du type H05VV F ou H05RR F de section 3x0 75 mm2 Le branchement au bornier doi...

Page 22: ...ESSION DE SERVICE DEBIT DIAM TER INJECTOR DIAM TER BY PASS ROBINET DEBIT CALORIFIQUES W EE gas burner N DESIGNATION mbar g h L h 1 100 mm 1 100 mm Max Min 2 SEMI RAPIDE G30 G31 28 30 37 126 65 31 1750...

Page 23: ...ar as crian as durante todo o tempo de funcionamento do aparelho cuidando para que n o estejam na sua vizinhan a e que n o toquem na superf cie antes da mesma estar totalmente arrefecida Antes de alim...

Page 24: ...ama grande fig 1 Queimador Pot ncia W Recipiente Auxiliar 1000 10 14 cm Semi r pido 1750 16 18 cm Triplo queimador 3800 24 26 cm Advert ncia Verificar sempre se o man pulo est na posi o de fechado ver...

Page 25: ...ue se encontram venda IMPORTANTE N o deixe nunca derramado na superf cie da placa por muito tempo l quidos como sumo de lim o ou tomate gua salgada vinagre caf ou leite pois podem danificar a superf c...

Page 26: ...ntacto c o m a s p a r t e s quentes do inv lucro d o f o r n o A l m disso no caso de instala o por cima de um forno sem ventila o for ada de refrigera o para consentir um adequado arejamento dever o...

Page 27: ...tente no aparelho Verificar se a instala o el ctrica possui um eficaz circuito de terra de acordo com os regulamentos em vigor A medi o da terra obrigat ria Se o aparelho estiver desprovido de ficha m...

Page 28: ...DELO MANUTEN O Substitui o do cabo de alimenta o No caso de substitui o do cabo de alimenta o deve utilizar se um cabo do tipo H05VV F ou H05RR F com a sec o de 3 x 0 75 mm2 A liga o placa de bornes d...

Page 29: ...o se responsabiliza por poss veis inexactid es imput veis a erros de impress o ou de transcri o contidas neste manual O Fabricante reserva se o direito de efectuar nos pr prios produtos as modifica es...

Page 30: ......

Page 31: ......

Page 32: ...29 COD 208776 07 06 2016...

Reviews: