5
The other one will be packed in the parts bag as spare parts
Please
We recommend you:
CHECK THAT THE WIND PAD IS CORRECT.
The
wind pad is found on the motor unit and must be installed with wind pad
A
in
the case of
RECIRCULATING mode
.
If change to exhaust way, disassemble the metal lamp board first, then
change the part A to part B, which is as spare in the manual bag. Take away
the air outlet cover and install the air outlet adapter with no-return valve.
FOR TWIN MOTORS MODEL
CHECK THAT THE
DUCTING-RECIRCULATING LEVER IS IN
THE RIGHT POSITION:
The lever is found on
the motor unit and must be positioned on the
symbol
F
in the case of installation in
recirculating
version.
If change to exhaust way, rotate the lever to ducting mode, symbol E.
Then take away one of the air outlets on top or rear. Install the air
outlet adapter with no-return valve.
·Also remember that the use of charcoal filter/s is not necessary with the
ducting version; if these are fitted, please remove them.