background image

                                     

                                                         

 

User manual

 

Default 

Restore  setting  status  of  :  regular,  encode, 

record, alarm, network, net service, GUI display, 

serial settings, account manage 

Import & 

Export 

Config import, Config export, Log export 

Upgrade 

To do net upgrade via IE or client software 

Reboot 

IPC soft reboot 

Info 

HDD info 

Show ttl space of HDD, type, space left, record 

time, etc 

Log 

Can base on record type and time to search log, 

can clear the log information 

Version 

Show alarm input output, system version, build 

date, etc 

 

Camera hardware notification: 

.

 

Power Port: DC power supply Status Indication Light: 

.

 

Red - power on or alarm activated 

.

 

Green - normally Working or Record 

.

 

Alarm Input: normal open(default) and close 

.

 

Alarm Output: alarm activated output 

.

 

RS485: PTZ or other RS485 devices 

.

 

Reset: Press on 5 seconds to reset to factory default settings, include IP settings 
Audio Input: connect with audio picker 

.

 

Audio Output: connect with speaker 

.

 

Video Output: BNC/TV output, use for adjust camera and view IP settings   

 

Summary of Contents for Smurf A Series

Page 1: ...User manual MyiHome AirLinkWiFi Smurf A Series H 264 Internet Wireless Camera NIGHT VISION REMOTE PAN TILT ROTATE User Manual Version 2 0 FCC ID AMU A1 CE R TTE ROHS...

Page 2: ...and use IP camera under temperature between 10 60 degree and humidity less than 90 Do not use IP camera in smoky or dusty environment Avoid collision or strong fall Please insure the IP Camera level...

Page 3: ...ed Untie the packing and checking the items contained against the following list Wireless IP Camera 1 Wi Fi Antenna If support in wireless 1 DC Power Supply 1 CD 1 Network Cable 1 Mounting bracket 1 N...

Page 4: ...lay Card 64M or above memory Recommendable Operating system Window2000 or Window XP or Vista 1 4 Hardware Instruction Follow the steps below to set up your camera hardware Make sure to follow each ste...

Page 5: ...takes approximately 30 seconds to start up 4 When the camera is powered and network cable plug correctly Its head will turn around and the Network Indicator LED is blank 2 Functions Real time surveill...

Page 6: ...l the software as instruction Default IP address 192 168 1 10 subnet mask 255 255 255 0 gateway 192 168 1 1 default login admin and password blank For safety sake when firstly log in please go to Acco...

Page 7: ...Client Range For Example Your AP Router IP address is 192 168 1 1 the DHCP range you can give at 192 168 1 200 3 5 IP Search Click Give any word for your Device name Select IP Address Click IP Search...

Page 8: ...should set at 34567 Click IP address from top list Click Add Device OK as below image 3 6 Device Monitor 3 6 1 End a list showed Devices Connect Successful 3 6 2 Monitor can be viewing maximum 64 cha...

Page 9: ...User manual 3 7 Record 3 7 1 Recording Storage setting Click Auto storage list as below image choose what you wish 3 7 1 Record Plan given a recording...

Page 10: ...User manual schedule 3 7 2 Select cameras list from left side Click from Plan Template list add schedule 3 7 3 Select Remote Playback or Local Playback...

Page 11: ...ce add By Name or By Time at left side Search Auto Recording files appear in a list Playback control button see detail in below chart 3 8 Remote Configure 3 8 1 Remote Networking by DDNS domain name C...

Page 12: ...ame or use free myihome org login account and password at each MyiHomeAirLink camera base paste up with a label Apply DDNS myihome org as below image 3 8 2 WiFi Setting 3 8 3 Remote viewing how to set...

Page 13: ...User manual 3 8 3 2 Enable UPNP from TCP IP Setting 3 8 3 3 Enable DMZ from Firewall setting giving a Host IP Address as below image...

Page 14: ...User manual 3 8 3 4 Port Forwarding set up as below image Remark 34567 is media port 34599 for 3G smart mobile phone remote viewing 8188 is for viewing at IE default is 80...

Page 15: ...static IP address Port 34599 by fixed User ID default is admin Password default is blank Max Channel 1 for camera 1 channel 2 for camera 2 3 10 Remote control CMS 3 10 1 Click 3 10 2 Add Zone name Se...

Page 16: ...User manual Main menu guideline Main Menu Submenu Function summary Record Record Set record config record type record period etc...

Page 17: ...ding snapshot PTZ Email sending FTP upload etc Alarm input Set alarm input channel and linkage parameters alarm output recording snapshot PTZ email sending FTP upload etc Alarm output Set alarm mode c...

Page 18: ...ess baud rate data bit stop bit parity RS485 Set protocol address baud rate data bit stop bit parity RS232 Set serial port function baud rate data bit stop bit parity Camera parameter Exposure mode Da...

Page 19: ...h log can clear the log information Version Show alarm input output system version build date etc Camera hardware notification Power Port DC power supply Status Indication Light Red power on or alarm...