AirKing VAL30 Important Instructions & Operating Manual Download Page 2

INSTALLATION INSTRUCTIONS

CAUTION:

 

MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE STARTING INSTALLATION.

SECTION 1

Preparing the Range Hood

1.  Unpack hood from the carton and confirm that all pieces are present. In addition to the 

range hood you should have:

 

 

2 -  Chimney Sections

 

 

1 -  Package containing: 

 

 

 

1 - duct collar

 

 

 

2 - chimney brackets

 

 

 

1 - Wire compartment

 

 

 

8 - #6 x 1" mounting screws with wall anchors

 

 

 

2 - #6 x 3/8" self threading screws (chimney upper)

 

 

 

3 - #8-32 screws

 

 

30" models: 2 - Aluminum Grease Filters (shipped installed)

 

 

36" models: 3 - Aluminum Grease Filters (shipped installed)

 

 

2 -  50 Watt Halogen Lamps

 

 

1 -  Instruction/Safety Sheet   

NOTE:

 Some hoods may be shipped with a protective plastic adhered to the range hood. It is 

recommended to leave this in place during installation to protect the hood from scratching. 
Remove when the installation is complete.

SECTION 2

Installing the Range Hood

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE STARTING INSTALLATION.

CAUTION:

WHEN CUTTING OR DRILLING INTO WALL DO NOT DAMAGE 

ELECTRICAL WIRING AND OTHER HIDDEN UTILITIES.

1.  Locate and mark the upper keyhole positions on the wall. If installing onto drywall, drill 

holes into wall using a 3/16" drill bit. Install wall anchors into the drilled holes (one for each 

hole). Install (2) provided #6 x 1" screws, leaving a 1/8" gap between the screw head and 

the wall. If installing into other material (brick, cement, plaster, etc.) choose an appropriate 

fastner capable of supporting the weight of the hood. Line up the keyholes in the hood with 

the screws and position in place. Hang the hood over the keyhole anchors and verify that the 

hood is centered, plum and level 

(Figure 1).

2.  With the hood hanging in place from the top screws, mark the location of the lower holes. 

If installing onto drywall, remove the hood and drill holes into wall using a 3/16" drill bit. 

Install wall anchors into the drilled holes (one for each hole). If installing into other material 

(brick, cement, plaster, etc.) choose an appropriate fastner capable of supporting the weight 

of the hood. Hang the hood over the keyhole anchors and verify that the hood is centered, 

level and the bottom holes line up with the anchors. Install the provided #6 x 1" screws into 

the anchors 

(Figure 2)

. Tighten all screws completely and reinstall the Grease filters

www.airkinglimited.com

6728025 Rev. K 1-16

2 of 12

SECTION 3

Ducting

CAUTION: 

ALL DUCTING MUST COMPLY WITH LOCAL AND 

NATIONAL BUILDING CODES.

CAUTION:

 TO REDUCE THE RISK OF FIRE, USE ONLY METAL 

DUCTWORK.

1.  Install the included duct collar to the hood with four of the provided #6 blunt tip screws 

(Figure 3).

1.  Connect the ducting to the duct collar and secure in place using tape to seal all joints 

(Figure 3).

NOTE:

 To achieve proper air flow, 6" round ducting is required. The duct connector is 5.8" in 

diameter (for 6" round ducting) and the center is located 3.1875" inches from the back wall.

CAUTION: 

ALWAYS DUCT THE FAN TO THE OUTSIDE THROUGH A 

WALL OR ROOF CAP.

SECTION 4

Wiring

CAUTION: 

ALL ELECTRICAL CONNECTIONS MUST BE MADE 

IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL 

ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL 
WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.

1.  Remove wire compartment cover by removing the screw then sliding it outward. Choose 

the most convenient electrical knockout and remove using a straight-blade screw driver.

2.  Run wiring from an approved source carrying the appropriate rating. One neutral (White), one 

ground (green or bare copper), and one hot (Black). Secure the electrical wires to the wire 
compartment with an approved electrical connector. Make sure you leave enough wiring in 
the box to make the connection to the hood.

3.  Connect the White wire from the range hood to the White wire from the supply, and the Black 

wire from the range hood to the Black wire of the supply. Connect the ground wire from the 
home (green or bare) and the Green wire from the range hood. Use approved methods for 
all connections. Reinstall the wire compartment by sliding the tabs back into the holes then 
reinstalling the screw that was removed eariler. Make sure all wiring is securely contained 
within the wire compartment 

(Figure 4).

Figure 1

Upper Keyholes

Side View

Figure 2

Holes

Side View

Figure 3

Duct Collar

Ducting

Hood

Summary of Contents for VAL30

Page 1: ...or unbalanced impellers keep drywall spray construction dust etc off power unit g Read all instructions before installing or using range hood WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK DO NOT...

Page 2: ...the hood Hang the hood over the keyhole anchors and verify that the hood is centered level and the bottom holes line up with the anchors Install the provided 6 x 1 screws into the anchors Figure 2 Tig...

Page 3: ...he chimney are secured in place on the indents of the vertical chimney bracket and the backside of the chimney fits between the hood and the wall with the bottom tabs overlapping the back lip of the h...

Page 4: ...r Filter If you have installed the optional charcoal odor filters they cannot be washed and must be discarded and replaced when they become noticeably dirty have stopped filtering the odors or at leas...

Page 5: ...PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD Some states and provinces do not allow limitations on how long an implied warranty lasts or the...

Page 6: ...www airkinglimited com 6728025 Rev K 1 16 6 of 12...

Page 7: ...atteindre l unit de puissance g Lire toutes les instructions avant d installer ou d utiliser la hotte de cuisine AVERTISSEMENT POUR R DUIRE LES RISQUES D INCENDIE OU DE CHOC LECTRIQUE NE PAS UTILISER...

Page 8: ...st centr e niveau et les trous inf rieurs alignent avec les ancrages Installez les vis fournies 6 x 1po dans les ancres Figure 2 Serrez toutes les vis compl tement et r installez les filtres de graiss...

Page 9: ...ure ce moment 3 Glissez la chemin e en place de fa on ce que les languettes de dessus de chemin e soient fix es en place sur les creux du support vertical de la chemin e et le derri re de la chemin e...

Page 10: ...de fa on remarquable qu ils aient cess de filtrer les odeurs ou au moins une fois par ann e Remplacer les filtres anti odeurs avec le mod le BCCF 02 de Air King Changement de la lampe Enlevez le couve...

Page 11: ...NTIE Certains tats et provinces ne permettent pas les limitations de la p riode de garantie ou l exclusion ou la restriction des dommages accidentels ou indirects et par cons quent les pr sentes restr...

Page 12: ...www airkinglimited com 6728025 Rev K 1 16 12 of 12...