background image

www.airkinglimited.com

6728076 Rev. Q 3/22

4 of 12

SECTION 9 (QFAM)

Setting the Controller 

(Energy Savings Mode Only)

Figure 12

Control Cover

Control Panel

If the main Access Panel has 

not already been removed, 

remove the screws securing 

the access panel cover in 

place and open the cover 

to gain access. Locate the 

Control Cover inside the unit. 

To access the control panel, 

pull the Control Cover down 

from the top 

(Figure 12).

In the normal operation display, press and hold the “SetT” button for 5 seconds to switch the 

temperature to Fahrenheit and Celsius units.
After pressing the “SetT” button, the display shows the setting 

value of the upper limit temperature. The following figure is 

displayed. Press the “-” or “+” buttons on both sides to adjust 

the upper limit temperature value.

Pressing the “SetT” button again, the lower limit temperature 

setting value is displayed on the display, as shown below. 

Press the “-” or “+” buttons on both sides to adjust the 

content of the lower limit temperature value.

After the setting is completed, 

press the “SetT” button to return 

to normal display.

Press the “SetH” button. The display shows the setting value of 

the upper limit humidity. The following figure is displayed. Press 

the “-” or “+” buttons on both sides to adjust the upper limit 

humidity value.

After pressing the “SetH” button again, the lower limit humidity 

setting value is displayed on the display, as shown on the right. 

Press the “-” or “+” buttons on both sides to adjust the lower 

limit humidity value.

After the setting is completed, 

press the “SetH” button to return 

to normal display. In the normal 

operation display, press and hold 

the “SetH” button for 5 seconds 

to switch the display position of 

temperature and humidity.

When the temperature is higher than 150°F (65°C), the display 

will  show “HI°F”. When the temperature is lower than 15°F 

(-10°C), the display will show “Lo°F”; when the humidity is lower 

than 10%, the display will show “Lo%”.

When the detection temperature sensor and humidity sensor are 

abnormal, “---” is displayed.

To restore the factory setting, make sure the unit is in the “OFF” setting. Hold the Energy 

Savings Button for approximately 5 seconds. 

  •  Default temperature setpoint range: 40°F (Low) - 90°F (High). 

  Low temperature setpoint adjustment range: 32°F - 55°F (0°C - 10°C). 

  High temperature setpoint adjustment range: 65°F - 95°F (18°C - 35°C)

  •  Default humidity setpoint range: 30% (Low) - 65% (High).  

  Low humidity setpoint adjustment range: 10%-50%.  

  High humidity setpoint adjustment range: 55%-80%

SECTION 10

Use and Care

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT SERVICE 

PANEL BEFORE SERVICING THE UNIT.

1. 

Cleaning the Fan Assembly:

 Wipe all parts with a dry cloth or gently vacuum the fan. 

NEVER IMMERSE ELECTRICAL PARTS IN WATER.

NOTE:

 If you notice a large amount of insects and debris in the insect filter, this could be a 

sign that the intake weather hood (roof cap or wall cap) might be compromised and need 

repair or replacing.
2. 

Optional Air Filter:

 If an optional air filter is installed, it should be checked every month 

and replaced at least once every 3 months. Reverse the instructions in the 

SECTION 6

 of 

these instructions to remove filter.

CALIFORNIA RESIDENTS ONLY:

WARNING:

 THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL [OR 

CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER.

WARNING:

 THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL [OR CHEMICALS] 

KNOWN TO THE STATE OF CALIFORNIA TO CAUSE REPRODUCTIVE TOXICITY.

Summary of Contents for FAS

Page 1: ...Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local co...

Page 2: ...t routing possible for best performance and avoid installing the fan with smaller ducts than recommended Insulation around the ducts can reduce energy loss and inhibit mold growth Fans installed with existing ducts may not achieve their rated air flow WARNING MAKE SURE THE FRESH AIR INTAKE PORT COMPLIES WITH ALL LOCAL AND NATIONAL CODES AND IS LOCATED AT LEAST 6 FEET AWAY FROM SOURCES OF CONTAMINA...

Page 3: ...present and for the temperature requirements of the installation to prevent air leakage from unconditioned spaces Additional material backing rod ceiling material are also not required NOTE This unit is equipped with a wire mesh insect screen Confirm that the screen is installed on the inside of the unit on the inlet ducting side 1 If the screen is not in place insert the screen into the tab at th...

Page 4: ...display press and hold the SetH button for 5 seconds to switch the display position of temperature and humidity When the temperature is higher than 150 F 65 C the display will show HI F When the temperature is lower than 15 F 10 C the display will show Lo F when the humidity is lower than 10 the display will show Lo When the detection temperature sensor and humidity sensor are abnormal is displaye...

Page 5: ...use unauthorized repairs made or attempted This warranty does not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY LAST ONE YEAR FROM THE DATE OF ORIGIN...

Page 6: ...0001 2 1 6 Metal Collar Intake 5S1650002 3 1 6 Metal Collar Outlet 5S1650003 4 1 Blower Assembly 5S2202013 5 1 Wire Compartment Assembly 5S1650100 6 2 Adjustment Knobs 5S1299802 7 1 LCD Controller QFAM 5S1650043 8 1 Insect Screen 5S1650005 9 1 Access Panel 5S1650044 REPLACEMENT PARTS DIAGRAM 3 1 1 4 2 5 6 7 8 9 ...

Page 7: ...t b Avant d effectuer un service ou de nettoyer l unité couper l alimentation électrique dans le panneau de distribution et verrouiller le dispositif de déconnexionafind éviterquel alimentationnerevienneaccidentellement Lorsque le dispositif ne peut être verrouillé fixer solidement un avis d avertissement tel qu une étiquette au panneau de distribution AVERTISSEMENT POUR RÉDUIRE LES RISQUES D INCE...

Page 8: ...ance et évitez d installer le ventilateur avec des conduits plus petits que recommandé L isolation autour des conduits peut réduire la perte d énergie et empêcher le développement de moisissures Il se peut que les ventilateurs installés avec des conduits existants n atteignent pas leur débit d air nominal AVERTISSEMENT ASSUREZ VOUS QUE LE PORT D ADMISSION D AIR FRAIS EST CONFORME À TOUS LES CODES ...

Page 9: ...exigences de température de l installation Des matériaux supplémentaires tige de support matériau de plafond ne sont pas non plus nécessaires REMARQUE Cette unité est équipée d un grillage pour moustiquaire Assurez vous que le grillage est installé à l intérieur de l unité du côté des conduits d entrée 1 Si le grillage n est pas en place insérez le grillage dans la languette située à la base de l ...

Page 10: ... la température est supérieure à 65 C 150 F l écran affichera HI F Lorsque la température est inférieure à 10 C 15 F l écran affichera Lo F lorsque l humidité est inférieure à 10 l écran affichera Lo Lorsque le capteur de détection de température et le capteur d humidité est anormal s affichera Pour rétablir les réglages par défaut s assurer que l unité est au réglage OFF Appuyer sur le bouton éco...

Page 11: ...ou arrête de fonctionner en raison d un accident d une mauvaise manipulation ou opération de dommages d expédition d abus de mauvaise utilisation de réparation faite ou tentées non autorisées Cette garantie ne couvre pas les coûts d expédition pour le retour des produits à Air King pour la réparation ou le remplacement Air King payera les frais d expédition de retour de Air King après les réparati...

Page 12: ... 6 po d admission 5S1650002 3 1 Assemblée de collier en métal de 6 po sortie 5S1650003 4 1 Assemblée de la Soufflante 5S2202013 5 1 Assemblée du compartiment du fil 5S1650100 6 2 Boutons de réglage 5S1299802 7 1 Contrôleur LCD QFAM 5S1650043 8 1 Écran pour les insectes 5S1650005 9 1 Panneau d accès 5S1650044 SCHÉMA DES PIÈCES DE RECHANGE 3 1 1 4 2 5 6 7 8 9 ...

Reviews: