AirKing AKF100D4 Operating Manual Download Page 5

www.airkinglimited.com

A210952014 Rev. L 8-17

5 of 12

Troubleshooting Guide

    Trouble 

 

Probable Cause 

 

Suggested Remedy

  1.  Fan does not operate when the switch is on. 

1a.  A fuse may be blown or a circuit tripped. 

1a.  Replace fuse or reset circuit breaker.

     

1b.  Connector plug from motor is not plugged in.  1b.  Turn off power to unit. Remove Grill and plug motor into receptacle

     

 

 

 

in housing. Restore power to unit.

     

1c.  Wiring is not connected properly. 

1c.  Turn off power to unit. Check that all wires are connected.

     

1d.  Motor has stopped operating. 

1d.  Replace motor.

  2.  Fan is operating, but air moves slower than normal. 

2. 

Obstruction in the exhaust ducting. 

2. 

Check for any obstructions in the ducting. The most common are bird nests

     

 

 

 

in the roof cap or wall cap where the fan exhausts to the outside.

  3.  Fan is operating louder than normal. 

3a.  Motor is loose. 

3a.  Turn off power to unit. Remove grill and check that all screws are fully

     

 

 

 

tightened. Restore power to unit.

     

3b.  Fan blade is hitting housing of unit. 

3b.  Call your dealer for service.

LIMITED WARRANTY

WHAT THIS WARRANTY COVERS:

 This product is warranted against defects in workmanship and/or materials. 

HOW LONG THIS WARRANTY LASTS:

 This warranty extends only to the original purchaser of the product and lasts for five (5) years from the date of original purchase or until the original 

purchaser of the product sells or transfers the product, whichever first occurs. 

WHAT AIR KING WILL DO:

 During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same 

or comparable model. 

WHAT THIS WARRANTY DOES NOT COVER:

 This warranty does not apply if the product was damaged or failed because of accident, improper handling or operation, shipping damage, abuse, 

misuse, unauthorized repairs made or attempted. This warranty does not cover shipping costs for the return of products to Air King for repair or replacement. Air King will pay return shipping 

charges from Air King following warranty repairs or replacement 

ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY), LAST ONE YEAR FROM THE DATE OF 

ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT, WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING’S 

LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER, OR (II) REPLACMENT OR REPAIR 

OF ANY HOUSE FUSES, CIRCUIT BREAKERS OR RECEPTACLES. NOTWITHSTANDING ANYTHING TO THE CONTRARY, IN NO EVENT SHALL AIR KING’S LIABILITY UNDER ANY EXPRESS 

OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.

Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so these exclusions or 

limitations may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state to state and province to province. Proof of purchase is 

required before a warranty claim will be accepted. 

CUSTOMER SERVICE:

Toll-Free (800) 465-7300

Our Customer Service team is available to assist you with product questions, service center locations, and replacement parts. They can be reached Monday through Friday, 8am-4pm Eastern. 

Please have your model number available, as well as the type and style (located on the label inside of your product). 

Please do not return product to place of purchase.

www.airkinglimited.com

PARTS FOR DISCONTINUED, OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE. DUE TO SAFETY REASONS, MANY ELECTRONIC COMPONENTS AND MOST 

HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT.

Installer: 

 

Installation Date: 

Place of Purchase: 

 

Model Number: 

Summary of Contents for AKF100D4

Page 1: ...ack drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Re...

Page 2: ...ends of the rails to the joists Figure 2 www airkinglimited com A210952014 Rev L 8 17 2 of 12 SECTION 4 Ducting NOTE 4 OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE CAUTION ALL DUCTING MUST...

Page 3: ...he Red wire light from the fan housing to the other side of the top switch and connect the Purple wire night light from the fan housing to the other side of the bottom switch Figure 10 NOTE The fan s...

Page 4: ...CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION 1 Cleaning the Grill Remove grill and dislodge reflector from grill by sliding the reflector notches from beneath...

Page 5: ...not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL...

Page 6: ...ing Channel 5S1202122 3 1 Collar Assembly 5S1299111 4 1 Wire Cover Assembly LEDAK100D AKF100D4 5S1202626 1 Wire Cover Assembly LED100DH 5S1250122 5 1 Blower Assembly 5S2202401 6 1 Light Assembly 5S120...

Page 7: ...t de l quipement de chauffage et les normes de s curit telles que celles publi es par la National Fire Protection Association NFPA et de la American Society for Heating Refrigeration and Air Condition...

Page 8: ...La canalisation de ce ventilateur l ext rieur du b timent a un effet important sur le flux d air le bruit et la consommation d nergie du ventilateur Utilisez la route de canalisation la plus courte e...

Page 9: ...pteur du haut et connectez le fil violet veilleuse du bo tier du ventilateur l autre c t de l interrupteur du bas Figure 10 REMARQUE les fils du r ceptacle du ventilateur pourraient n cessiter d tre t...

Page 10: ...U DE SERVICE AVANT DE COMMENCER L INSTALLATION 1 Nettoyage de la grille Retirer la grille et utiliser un d tergent doux tel que du liquide pour la vaisselle puis s cher l aide d un chiffon doux NE JAM...

Page 11: ...aise utilisation de r paration faite ou tent es non autoris es Cette garantie ne couvre pas les co ts d exp dition pour le retour des produits Air King pour la r paration ou le remplacement Air King p...

Page 12: ...2626 1 Assembl e du compartiment du fil LED100DH 5S1250122 5 1 Assembl e de la Soufflante 5S2202401 6 1 Assemblement de lumi re 5S1202799 7 1 Joint Ext rieur 5S1202043 8 1 Assemblement de grille 5S120...

Page 13: ...proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such a...

Page 14: ...to the joists Figure 2 www airkinglimited com 210572203 Rev V 8 17 2 of 12 SECTION 4 Ducting NOTE 4 OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE CAUTION ALL DUCTING MUST COMPLY WITH LOCAL...

Page 15: ...oved methods for all connections 3c From where you have chosen to access the fan s junction box connect the White wire from the house to the two White wires from the fan Connect the ground wire green...

Page 16: ...setting the fan will turn on and run until the humidity level falls below this setting 3 Reinstall the grill and restore power SECTION 8 Use and Care CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVIC...

Page 17: ...not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL...

Page 18: ...1 Wire Cover Assembly LEDAK100 5S1202622 1 Wire Cover Assembly LEDAK80H 5S1202623 1 Wire Cover Assembly LEDAK100H 5S1202624 5 1 Blower Assembly LEDAK50 5S2202029 1 Blower Assembly LEDAK80 5S2202401 1...

Page 19: ...r pr venir un refoulement Suivre les directives du fabricant de l quipement de chauffage et les normes de s curit telles que celles publi es par la National Fire Protection Association NFPA et de la A...

Page 20: ...10572203 Rev V 8 17 8 of 12 SECTION 4 Conduits REMARQUE UN CONDUIT PLUS RIGIDE DE 4 PO OU PLUS EST RECOMMANDE POUR UNE MEILLEURE PERFORMANCE ATTENTION TOUS LES CONDUITS DOIVENT TRE CONFORMES AUX CODES...

Page 21: ...des m thodes approuv es pour toutes les connexions 3c De l o vous avez choisi d acc der la bo te de raccordement du ventilateur raccordez le fil blanc de la maison aux deux fils blancs du ventilateur...

Page 22: ...it de la salle est inf rieur ce r glage le ventilateur restera teint Lorsque le niveau d humidit monte ce r glage le ventilateur s allumera et fonctionnera jusqu ce que le niveau d humidit tombe au de...

Page 23: ...vaise utilisation de r paration faite ou tent es non autoris es Cette garantie ne couvre pas les co ts d exp dition pour le retour des produits Air King pour la r paration ou le remplacement Air King...

Page 24: ...l LEDAK100 5S1202622 1 Assembl e du compartiment du fil LEDAK80H 5S1202623 1 Assembl e du compartiment du fil LEDAK100H 5S1202624 5 1 Assembl e de la Soufflante LEDAK50 5S2202029 1 Assembl e de la Sou...

Reviews: