Rev. A 9/05
1
2084779
DIGITAL RECIRCULATING HUMIDIFIER
9 GALLON MODEL 3LA79A/9929A
READ AND SAVE THESE INSTRUCTIONS
OPERATING INSTRUCTIONS & PARTS MANUAL
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
DESCRIPTION
The AirKing 9 Gallon (34.1 liter) Humidifier features 3-Speed whisper
quiet operation. This unit is capable of humidifying up to 3200 sq. ft.
(355.6 sq. yards) and features a 7.5 ft. (2.3 m) 18/3 cord set.
SPECIFICATIONS
Motor .................................... 120V, 50/60 Hz
Blade diameter .................... 9" (22.86 cm)
Speeds ................................. 3
Control ................................. Rotary Switch
Approvals ............................. UL/CUL Listed
MODEL
3LA79A/9929A
SPEED
HIGH
MED
LOW
RPM
1300
1100
900
Amps
0.590
0.500
0.450
Watts
62.8
58.8
49.8
dB A
61
59
53
NOTE: A few droplets of water may be present
in your Humidifier as a result of our quality
testing prior to packaging and shipment.
DO NOT pour water into Grill. DO NOT spill water on Control Panel.
Water should only be poured into the Unit using the Jug.
CAUTION: DO NOT fill unit
before assembling.
1. Remove Water Jug then,
Upper Housing from base
of unit.
(Figure 1)
2. Lay base of unit on it’s side
so the bottom of the unit
is facing you.
3. Fully insert the four Castors into
the holes in the bottom of the unit.
(Figure 2)
4. Replace Upper Housing, then Wa-
ter Jug into unit.
ASSEMBLY
Figure 1
Base
Upper Housing
Water Jug
MODEL 3LA79A/9929A
TROUBLE
PROBABLE CAUSE
SOLUTION
Fan not working or
•
No power
Make sure Unit is plugged in
Humidifier doesn’t
Check that the Power Switch is On
turn on
•
Humidistat not set correctly
Set Humidistat to higher humidity level
•
Top of Humidifier not seated properly
Make sure top is properly seated on Base
on Base (Unit is equipped with an
automatic shut off)
•
Filter Holder not assembled properly
Make sure Filter Holder is seated in place
or is missing (Unit is equipped with an
automatic shut off)
Water leaking
•
Base is overfilled
Reduce water level in Base
•
Filter is old and dirty
Replace Filter
Foul odor
•
Filter needs to be replaced
Replace Filter
•
Base needs to be cleaned
Follow Instructions in CLEANING section
•
Whole Humidifier needs cleaning
Follow Instructions in CLEANING section
Filter discoloration
•
Mineral deposits in water
Replace Filter
Water discoloration
•
Humidifier needs to be cleaned
Follow Instructions in CLEANING section
•
Hard water - Iron in water
Use filtered or distilled water
•
Some humidifier additives can cause
discoloration
Lights do not work:
Humidistat Light Off,
•
Humidity is not yet achieved in room
Allow Humidifier to continue running
Power Light On
Power Light Off,
•
Room has reached desired
Set Humidity Knob for more Humidity
Humidistat Light On
Humidity level
No water show
•
No water in Unit
Refill Unit
•
Hose not connected to Pump
Connect Hose to Pump
•
Hose not connected to Water Show
Connect Hose to Water Show
TROUBLE SHOOTING GUIDE
Figure 2
Hole
Castor
Rev. A 9/05
4
2084779
1
2010598
Humidifier Top
1
2
02091220I
Screw #8 x 1/2 PPH Type 30A ZP
15
3
02030008EG Motor/Control Box Assembly
1
4
2010588
Chassis
1
5
2010590
Drip Shield
1
6
2010591EG
Base
1
7
2010592
Front Filter Holder
1
8
2010593
Rear Filter Holder
1
9
02010860S
Lever
1
10
02010861
Spring
1
11
02010862
O-Ring
1
12
02010871
Plunger
1
13
2010844
Jug
1
14
2010597
Jug Top
1
15
2010596
Jug Lid
1
16
02010868S
Water Distribution Block
1
17
02010869S
Water Show Assembly
1
18
2010870
Filter
1
19
2011073
Blade
1
20
2011074
Basket
1
21
2069093
Tube 1/4” x 24 1/2”
1
22
2069094
Tube 1/4” x 15 1/2”
1
23
02091221I
Screw #8 X 3/4” PTH Type 30A ZP
7
24
02098038
Castors
4
25
02010601
Handle
1
26
02010867S
Impellor
1
27
02010866LS Lower Pump Housing
1
28
02010866US Upper Pump Housing
1
KEY PART NO.
DESCRIPTION
QTY.
1
2
3
4
16
21
2
5
6
19
20
23
3
22
17
28
26
27
25
14
13
12
11
15
10
9
7
8
18
24
GENERAL SAFETY INFORMATION
1. Make certain that the power source conforms to the electrical require-
ments of the Humidifier.
2. The power cord is equipped with a three-prong grounded plug that
must be inserted into a matching receptacle. Under no circum-
stances must the grounding prong be cut off the plug. Where a two-
prong wall receptacle is encountered, it must be replaced with a
properly grounded three-prong receptacle installed in accordance
with the National Electrical Code (NEC) and all applicable local
codes and ordinances. This work must be done only by a qualified
electrician, using copper wire only.
WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER
IS NOT RECOMMENDED. IMPROPER CONNECTION MAY CREATE
THE RISK OF ELECTROCUTION. USE OF SUCH ADAPTERS ARE
NOT PERMITTED IN CANADA.
WARNING: THIS PLUG IS A SAFETY FEATURE. TO REDUCE THE
RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY, DO NOT
REMOVE, REPLACE, REPAIR OR TAMPER WITH THE ORIGINALLY
SUPPLIED PLUG. IF THE FAN DOES NOT FUNCTION PROPERLY, IT
MAY BE DUE TO THE SAFETY DEVICE INCORPORATED IN THIS
PLUG. RETURN TO AN AUTHORIZED SERVICE CENTER OR CALL
800-233-0268, MONDAY - FRIDAY, BETWEEN 8:00 AM AND 5:00 PM
EST. IF THE PLUG WARNING LABEL IS MISSING OR DAMAGED,
CALL THE TOLL FREE NUMBER FOR A REPLACEMENT LABEL.
3. Where possible, avoid the use of extension cords. If they must be
used, minimize the risk of overheating by ensuring that they are UL
listed and of the proper gage and length. Never use a single extension
cord to operate more than one Humidifier.
4. Do not insert fingers or foreign objects into the Humidifier. Do not block
or tamper with the Humidifier in any manner while it is in operation. Do
not touch the Humidifier while in operation or just after it has been
turned off, as some parts may be hot enough to cause injury.
5. Unplug power cord before filling or servicing the Humidifier.
WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE SOLE
MEANS OF DISCONNECTING POWER WHEN FILLING OR SERVICING
THE HUMIDIFIER. ALWAYS UNPLUG THE POWER CORD.
6. This Humidifier is intended for general use ONLY. It must NOT be
used in potentially dangerous locations such as flammable, explo-
sive, chemical-laden or wet atmospheres.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT USE THIS HUMIDIFIER WITH ANY SOLID STATE SPEED
CONTROL DEVICE.
7. Always place the Humidifier is on a stable, flat, level surface when
operating, to avoid the chance of the Humidifier overturning. Locate
the Power Cord so the Humidifier or other objects are not resting on it.
Keep the Power Cord away from room traffic.
8. Always direct air flow away from walls and furniture. Excessive moisture
may cause damage.
9. Completely reassemble Humidifier, according to instructions, before
reconnecting to power supply.
10. Humidifiers require regular cleaning to maintain proper operating condi-
tions. Refer to the CLEANING section for proper cleaning procedures.