CHAPTER 1 
 

GENERAL SAFETY 
INSTRUCTIONS  

1.0  

 

Important information

 

To ensure a proper function and your own safety manual should be thoroughly read 
and observed.  
This document is part of the product and has to be available and durable at all times 
to ensure  a safe operation of the fan. All equipment-related safety regulations must 
be adhered to. 

 

 
 

1.1 

 

Warnings 
The  adjacent  symbols  are  safety  warnings.  To  avoid  any  risk  of 
injury and dangerous situations,  all safety  regulations (symbols) 
in this document must be strictly observed. 

 

 
1.2 

 
Safety Instructions  

For  use,  connection  and  operation  apply  special  regulations.  If  in 
doubt, contact manufacturer for advice. Other information is relevant to 
standards and legislative texts. 

 

For all work involving operation of the fan, general applicable 

safety and accident prevention regulations must be observed.  

 

All  electrical  work  and  commissioning  must  be  carried  out 
only by authorized and qualified electricians.  

 

Maintenance and installation work must be carried out only by 
competent personnel. 

 

Before  cleaning,  maintenance  and  installation  work  or  before 
opening  the  terminal  compartment  following  points  must  be 
observed: 
-  Disconnect  the  fan  from  power  supply  (all-pole)  and  secure 
against restarting! 
- Wait till the work stoppage of rotating parts! 
-  After  work  stoppage  of  rotating  parts,  waiting  period  of  3 
min.  has  to  be  observed;  dangerous  voltages  can  occur  by 
internal capacitors even after disconnection from the network! 

 

All equipment-related safety regulations must be observed!  
If  necessary,  further  country-specific  regulations  must  be 
complied with!  

 

Contact  protection  (or  Protection  against  accidental  contact) 
must be insured according to DIN EN 13857 (see Chapter 2.1)!   
Contact with rotating parts must be avoided.

 

     

 

 

 

 DANGER

 

WARNING 

CAUTION 

 DANGER

 

Summary of Contents for QT 150VS

Page 1: ...nd Operating Instructions QuietAir 150mm Axial Fan MODEL QT 150VS Variable Speed Fan 50 260m3 hr With Adjustable Timer control Variable Speed with timer Low Energy Quiet Long Life Extra Safe 80000309...

Page 2: ...ance Chapter 3 SPECIFICATIONS DIMENSIONS M1 150 0 10V 3 0 Specifications 3 1 Product lifetime 3 2 Accessories 3 3 Dimensions Chapter 4 FUNCTION 4 0 Function description Chapter 5 CLEANING DEINSTALLATI...

Page 3: ...and accident prevention regulations must be observed All electrical work and commissioning must be carried out only by authorized and qualified electricians Maintenance and installation work must be c...

Page 4: ...rly installed and used for its intended purpose product complies with the valid regulations and CE guidelines at the time of its production 1 5 Transport The fan is factory packed so that it is protec...

Page 5: ...ectrical data this must be conformed to the local supply network On the test stand fan performance was complied with DIN EN ISO 5801 1 10 Noise data The noise data which relate to distances is valid u...

Page 6: ...on inhibit activates the fan for 15 sec to protect the motor from rapid on off switching CHAPTER 3 SPECIFICATIONS DIMENSIONS M1 150 0 10 V 3 0 Specifications Impeller 137 Electrical supply NYM 0 2 x1...

Page 7: ...be limited internally via internal potentiometer settings In delivery condition the full scope of the control range becomes available 2 Scaling Scaling can be set through the internal potentiometer i...

Page 8: ...sible housing parts the external housing of the fan with a damp cloth Do not use any aggressive paint solvent cleaning agents High pressure cleaner or spray water is not permitted 5 1 Cover Dismantlin...

Page 9: ...ter unpacking and before installation the following points must be checked if any transport damage is noticed broken or bent parts free running of the impeller 6 2 Installation The QuietAir 150 is des...

Page 10: ...and wall plugs 3 Backdraft shutter and guide vane If required backdraft shutter scope of delivery can be installed behind the guide vane fig 6 During the housing installation the guide vane must be mo...

Page 11: ...must take place in one wire Insertion of 2 wires in the grommet is not allowed In the wiring make sure that wires are placed not on the board but on the edge along the housing fig 9 10 For LiYY contr...

Page 12: ...with supply cable through NYM O 4 1 5mm 2 Relays with low voltage consumers Connection combined with control line through LiYY 5 0 34mm 2 Wire transfer not over the board 1 Insert and tighten the ter...

Page 13: ...an the following need to be checked regularly Appearance of dust or dirt in the housing on the motor and impeller Free running of the impeller Appearance of excessive vibration and noise In case of pr...

Page 14: ...rminal N L Terminal N and L have to be connected to the 230V operating voltage Terminal 5 Terminal 1 activates the low stage Terminal 6 Terminal 2 activates the high stage Terminal 7 10 VDC Terminal 3...

Page 15: ...rocessing work wherein the setpoint of 10 V the controller will reach the maximum value of 100 Thus in the delivery state complete bandwidth set is available for both setpoint input and speed control...

Page 16: ...peed Note Minimum air operation and minimum rate of air can be achieved by electronic temperature sensors such as the ETR Type see accessories 4 Relay output An operating message will be displayed on...

Page 17: ...5 Schematic overview for QuietAir QT150 VS Fig 17...

Page 18: ...failure in Chapter 8 1 Bearing noise Vibrations see Chapter 8 1 Power consumption according to the specifications on the type plate see Chapter 8 1 8 1 Troubleshooting Safety instructions listed in C...

Page 19: ...ion mechanical loading fatigue and or other effects that could not be directly discerned should be disposed in accordance with local and international laws and regulations The same applies to auxiliar...

Page 20: ...le electrical supply 3 Has not been subjected to issue neglect or damage 4 Has not been modified or repaired by any person not authorised by Airflow Developments Ltd 5 Has been installed in accordance...

Reviews: