 Installation and Operating Instructions                                                                                         

        

  

 

 

Ensure a uniform inflow and free outlet! 

 

During operation within a fire place in the ventilated room, 
sufficient air supply should be provided in all operating 
conditions (please contact chimney sweep).    
Valid local regulations and laws should be observed! 

 

 
 

1.3 

Warranty claims – Disclaimer  

All  versions  of  this  manual  should  be  observed;  otherwise  the  guarantee  will  be 
annulled. The same applies to liability claims against Airflow Developments Limited. 
Any  potential  damages  are  not  a  subject  of  the  guarantee.  Changes  and 
modifications to the product are not allowed and will result in a loss of conformity - in 
such case any warranty and liability will be excluded.    

 

1.4 

Regulations – Guidelines 

The fan should be properly installed and used for its intended purpose. The product 
complies with the valid regulations and CE-guidelines at the time of its production.    

 

1.5 

Transport  

The fan is factory-packed so that it is protected against normal transport loads. It is 
recommended to leave the fan in the manufacturer’s original package.

  

 

1.6 

Acceptance of delivery  

A visual inspection  upon delivery should be  performed including damage and type 
accuracy check. In the event of there being any damage, the necessary notification 
of  claim

 

 immediately  has  to  be  reported  to  the  carrier.  Any  delay  in  complaint  will 

result in a loss of benefit entitlement.  

 

1.7 

Storage  

When  storing  for  a  long  period  of  time,  avoid  harmful  impacts  by  following  these 
steps: protect the motor by dry, air and dustproof package (plastic bags with drying 
agent and moisture indicator). The product should be stored in a vibration-free and 
water-protected premise at a constant temperature ranging from -20

C up to + 40

C.        

In  compliance  to  Chapter  8,  when  storing  a  product  for  more  than  three  months 
(motor standstill), maintenance should be determined before commissioning. In case 
of transshipment (especially over longer distances: e.g. sea), the packaging has to 
be checked whether it is suitable for transport and on the route. Damages caused by 
improper transportation, storage or installation are not covered by the warranty. 

 

1.8 

Operational area  
- Appropriate use: 

QuietAir  150  fans  are  used  to  convey  normal  or  slightly  dusty  (particles  size  <  10 
µm), little aggressive and  humid air,  into moderate climate and suitable area of its 
performance curve (see Airflow sales documentation / Internet). Operation permitted 
only for fixed installation within buildings. Maximum permitted medium and ambient 
temperature is 40ºC. QuietAir 150 fans conform to protection rating IP45, protection 
class II and according to VDE0100 part 701 can be installed in zones 1 and 2 of your 
wet room.    

 

 
 

 

Summary of Contents for QT 150T

Page 1: ...Instructions QuietAir 150mm Axial Fan MODEL QT 150T TwoSpeed Fan 220 260m3 hr With Delay Start and Adjustable Timer control Basic Switching with timer Low Energy Quiet Long Life Extra Safe Interval Ti...

Page 2: ...ion Chapter 3 SPECIFICATIONS DIMENSIONS 3 0 Specifications 3 1 Product lifetime 3 2 Accessories 3 3 Dimensions Chapter 4 FUNCTION 4 0 Function description Chapter 5 CLEANING DEINSTALLATION 5 0 Cleanin...

Page 3: ...applicable safety and accident prevention regulations should be observed All electrical work and commissioning should be carried out by authorized and qualified electricians Maintenance and installati...

Page 4: ...the necessary notification of claim immediately has to be reported to the carrier Any delay in complaint will result in a loss of benefit entitlement 1 7 Storage When storing for a long period of tim...

Page 5: ...n work must be carried out only by an approved electrician The QT150T should not to be used by children and persons with reduced physical mental or sensory capacities without proper practical experien...

Page 6: ...Protection class II Power input W 10 6 Weight approx kg 1 2 Rated current mA 100 70 Rotational speed 1900 1600 Flow volume m3 h 260 220 Shut down min 6 10 15 21 adjustable Interval H 0 8 12 24 adjust...

Page 7: ...ges the run on time will be ignored By mutual shut down of the both stages the run on time will be considered only when time function will be activated on both stages 4 Intermittent operation The fan...

Page 8: ...8 Installation and Operating Instructions All of the following information and instructions are intended for use by authorized electricians Fig 1 Fig 2...

Page 9: ...lation unit After unpacking and before installation the following points must be checked if any transport damage is noticed broken or bent parts free rotation of the impeller 6 2 Installation The QT15...

Page 10: ...on Commissioning Safety instructions listed in Chapter 1 2 should be observed All electrical installations to be carried out by an approved electrician in accordance with presented manual and wiring d...

Page 11: ...of the device Check the rotation of the impeller All parts of the fan especially screws and protective grid must be checked for tightness Do not mislay the screws included with the unit Ensure that t...

Page 12: ...tches 7 and 8 are activated 4 Push button operation If there is no switch on delay DIP 1 2 off off activated then switch inputs 1 or 2 can be controlled by a push button For this relevant stage time f...

Page 13: ...pon connection of the operating voltage the fan is for 1 min in a test mode prerequisite DIP switches factory settings see SS 1081 In this case switch on delay and run on time functions are within the...

Page 14: ...parts Firm seating of bolt connections loosen screws Housing quality cracks brittleness of the plastic Overrunning of the impeller the impeller doesn t run freely note possible causes of failure in C...

Page 15: ...ng Winding is short circuiting the motor Contact Airflow Technical Support Damaged cable or connector Replace parts if necessary replace motor Contact Airflow Technical Support Connected incorrectly C...

Page 16: ...nected to an unsuitable electrical supply 3 Has not been subjected to issue neglect or damage 4 Has not been modified or repaired by any person not authorised by Airflow Developments Ltd 5 Has been in...

Page 17: ...ement by an assessed and registered Competent Person should follow a Best Practice process and adopt air flow measurement Method A The Unconditional Method using a suitable UKAS certified measuring in...

Reviews: