background image

Remove termination cover, see Fig. A. (Screws 
marked with 1, 2, 3.)

Fig. A

5.

Cable (3 core flex) to be placed as shown in  
Fig. B. Electrician to make electrical connections 
(3 core 1mm

2

 flex, Ø7mm [17/64”] specified) as 

shown in Fig. C. Stripped ends to be kept to a 
minimum. Replace termination cover. 

Fig. B

Using template, cut hole in glass ø230 ± 2mm. 
Slide internal clamp over your arm as shown. 
Fold external clamp and insert through the hole 
in the window pane.

Make sure the seal of external clamp is against 
the glass, then align and insert the bolts through 
internal clamp. Brass nuts supplied should then 
be connected to bolts and finger tightened only.

If required, apply liquid or similar soap to foam 
seal on inside of external clamp. Carefully 
slide cylindrical window grille outlet end of 
fan assembly through opening. With screws 
provided, attach fan assembly to window clamp 
assembly (4 places).

1.

4.

2.

3.

Fan 
assembly

Apply soap to 
the foam seal

Internal 
clamp

External 
clamp

Finger 
tighten 
only

Screws 
marked 1, 
2, 3, retain 
the terminal 
cover to the 
chassis.

Break tab for 
cable access

7105A 

Auto Switched

 & 7107A

 Pull-Cord Switched 

MaxAir Window Exhaust Fan

 Installation Instructions

© Clipsal Australia Pty Ltd

Reviews: