USER MAINTENANCE  AND SENSOR ADJUSTMENT

 

Before starting work ensure the fan is disconnected from the power 
supply.

 

Cleaning should be done with a soft cloth wet with soap solution; after that, the 
surfaces  should  be  rubbed  dry.  The  blades  of  the  fan  need  careful  cleaning 
each 6 months. For this purpose, it is necessary to take the blade wheel off the 
motor shaft (holding it by the boss). The blades should be cleaned with

 

solution of water and a detergent. Please avoid water entry on the motor.

 

 

 

 

 
 
 

T

 

Fig. 5.1

 

The fan with timer 

options switches on when the voltage is 

supplied to clamp LT. After the voltage is disconnected  the fan 

continues  working during the time T, which is regulated from 2 
till 30 minutes. The time T is regulated by turning the 
potentiometer clockwise to increase  and anticlockwise  to 
decrease  the delay time (Fig. 5.1) 

 

 

The fan with timer and humidity sensor 

switches on when voltage is supplied to 
clamp LT or when the definite humidity 
level ( regulated from 60% till 90 %) is 
exceeded. After the voltage is 

 

 
 

60%

 

H min

 

 

H max

 

90%

 

 

 

H   extreme 

right 
position

 

T

 

H

 

Fig. 5.2

 

disconnected or humidity level H is decreased, the fan continues 
working during the time set by timer T, which is regulated from 
2 till 30 min. The options of time T and humidity H are regulated 
by turning the potentiometers T and H clockwise to increase and 
anticlockwise to decrease the delay time and humidity level 

respectively. To set the maximum humidity level the potentiometer H has to be 
set in position H max (90%). 

Attention! 

If during the regulation the potentiometer H is set outside  of the 

indicated zone rightwards from H max there is a probability that the fan will not 
switch on. In this case, it is necessary to check the position of the potentiometer 
(Fig. 5.2). 

 

 
 
 
 

T

 

 

Fig. 5.3

 

The fan with the timer and movement sensor 

switches on

 

when a person moves at the distance from 1 till 4 meters with 
viewing angle of the sensor of 100° horizontaly. After the 
person stops moving the fan continues working during the set 
time T, which is regulated from 2 till 30 minutes. The time T is 
regulated by turning the potentiometers clockwise to increase 
and anticlockwise to decrease the delay time (Fig. 5.3)

 

 

Summary of Contents for Aura-eco

Page 1: ...9041411 INSTALLATION OPERATING INSTRUCTIONS Aura eco 100mm 150mm Axial Fans ...

Page 2: ...r rooms heated in wintertime Fans are exhaust fans and are designed for wall or ceiling mounting Fig 6 7 They are designed for a long duration operation without disconnection from the power network The fan design is being constantly improved therefore some models may slightly vary from those described in the present specification Set of supply The following article is included Fan 1pc User s manua...

Page 3: ...d connection dimensions are listed in the tables 2 3 and at the Fig 1 2 The fans are designed for the connection to the AC network with the voltage of 220 240 V and current frequency of 50 Hz Table 2 Max air intake m 3 h Max pressure Pa Nominal power W Noise level dBA 60 35 6 26 235 86 20 35 The fans are designed for use in the premises with temperature from 0 C to 45 C The fans do not interfere w...

Page 4: ...Table 3 Type Dimensions mm Weight kg a b c d e Aura eco air 100 150 122 102 100 17 0 56 Aura eco air 150 205 174 124 150 19 0 9 Overall and connection dimensions Fig 2 1 1 Timer with motion sensor Fig 3 ...

Page 5: ...ork connections to fan spigot Precautions must be taken to avoid the black flow gases into the room from the open flue of gas or other fuel burning appliances PREPARATION OF DEVICE OPERATION Attention All work must be carried out with the equipment fully isolated from the power supply The electrical connection is to be carried out in accordance with the relevant wiring diagram and are only to be d...

Page 6: ... switch Diagram of the connection of Aura eco fan with timer timer with humidity sensor with built in switch connection of Aura eco fan 100 150 B L LT N connection of Aura eco fan 100 150 T HT L N Diagram of the connection of Aura eco fan with timer timer with motion sensor without built in switch connection of Aura eco fan 100 150 PRT L LT N ...

Page 7: ... exceeded After the voltage is 60 H min H max 90 H extreme right position T H Fig 5 2 disconnected or humidity level H is decreased the fan continues working during the time set by timer T which is regulated from 2 till 30 min The options of time T and humidity H are regulated by turning the potentiometers T and H clockwise to increase and anticlockwise to decrease the delay time and humidity leve...

Page 8: ...Fig 6 Fig 7 ...

Page 9: ...Fig 8 Fig 9 ...

Page 10: ...Fig 10 ...

Page 11: ...ply 3 Has not been subjected to misuse neglect or damage 4 Has not been modified or repaired by any person not authorised by Airflow Development Ltd 5 Has been installed in accordance with Building Regulations IEE wiring regulations Airflow Developments shall not be liable for any loss injury or other consequential damage in the event of a failure of the equipment or arising from or in connection ...

Reviews: