SAFETY REQUIREMENTS
The fan “Aura-eco” complies with the requirements according to the EU
norms and directives.
Level of protection from access to hazardous parts and waterproof is to
IPX4
Connection of fans supplied with the electric cords to power supply as well as
replacement of electric cord should be perfomed by a competent person
(Part P) and in accordance with latest IEE wiring regulations. A 3 amp fused
isolator should be fitted.
Fan operation beyond the operational temperature range as well as in rooms
with ambient air containing aggresive mixture is prohibited.
Precautions must be taken to avoid the black -flow of gases into the room
from the open flue of gas or other fuel-burning appliances.
Attention:
Ensure impeller rotates freely. Do not overtight on
ductwork connections to fan spigot.
Precautions must be taken to avoid the black -flow gases
into the room from the open flue of gas or other fuel-
burning appliances.
PREPARATION OF DEVICE OPERATION
Attention:
All work must be carried out with the equipment fully
isolated from the power supply. The electrical connection
is to be carried out in accordance with the relevant wiring
diagram and are only to be done by a certified electrician.
The electrical connection must be fully isolated from the
supply up to the final assembly!
All relevant safety regulation, national standards and norms are to be adhered
to. An appliance is required for cut off from the supply with a minimum of 3mm
contact opening of each pole.
The rated voltage and frequency must correspond with the data on the type
plate. The insertion of mains supply cable is carried out via a cable grommet
which is included in the delivery. Never lead cable over sharp edges. The
equipment corresponds to protection IPX4.