Uno hab Ext. Wall Ins. Vent Kit

Installation and Operating Instructions

4

© Airflow

 

-

 

we reserve the right to make changes without prior notice

DANGER

 

WARNING

 

CAUTION

 

DANGER

 

1.0  IMPORTANT INFORMATION

In order to ensure complete and effective operation and for your own safety, all of the following instructions should 

be read carefully and observed. 

This document should be regarded as part of the product and as such should be kept accessible and durable to 

ensure the safe operation of the fan. All p

roduct

-related safety regulations must be observed.

1.1 Warning instructions 

The accompanying symbols are safety-relevant prominent warning 

symbols. All safety regulations and/or symbols in this document must 

be absolutely adhered to, so that any risks of injury and dangerous 

situationsare avoided!

1.2 Safety instructions

Special regulations apply for use, connection and operation; consultation 

is required in case of doubt. Further information can be found in the relevant 

standards and legal texts. 

With regard to all work on the fan, the generally applicable safety at work 

and accident prevention regulations must be observed! The following 

points must be observed:

• When creating the wall opening, protect the installation site/ building

exterior against falling brickwork. Install protective cover!

• Remove objects from the immediate vicinity of the building exterior.

1.3  Area of application

– Intended use:

The wall installation units 

Uno hab

 are intended for external building wall installation. The air outlet is in the window

soffit through a stainless steel wall grille. A lockable plastic panel serves this purpose on the internal side of the wall

with an integrated non-woven air filter class G3 and sound insulation. In order to ensure balanced ventilation, at least

2 units, which operate in 

modes 

with regard to operating 

mode

 (supply air/extract air), are required for one residential

unit. Depending on the overall ventilation requirement of the residential unit, more than 2 units are normally installed

and the individual volume flows are automatically adjusted by means of the central control unit.

The standard equipment allows installation and use in frost-free rooms  >+ 5 °C.

When operating under difficult conditions, such as high levels of humidity, long standstill periods, excessive loads

and climatic, technical or electronic influences, 

seek approval from Airflow technical services

, as the standard

version is not suitable for this.

Any use other than the intended use is prohibited!

– Reasonably foreseeable misuse:

Ventilation units 

Uno hab

 are not suitable for operation under difficult conditions, such as high levels of humidity,

aggressive media, long standstill periods, heavy contamination, excessive loads due to climatic, technical or elec-

tronic influences. The same applies for the mobile use of fans (vehicles, aircraft, ships, etc.). Usage under these

conditions is only possible with approval from Airflow, as the standard version is not suitable in this case.

– Improper, prohibited use:

Improper, prohibited use:

Any use other than the intended use is not permitted! The conveying of solid matter or solid matter content > 10µm

in air and liquid is not permitted. Transport media, which affect the materials of the fan, and abrasive media are not

per- mitted. Use in explosive atmospheres is not permitted!

1.4  Personnel qualification

 m 

DANGER!

The electrical connection and start-up must only be carried out by qualified electricians.

Installation, servicing and maintenance of the fan must only be carried out by qualified electricians. 

 

Uno hab

 individual room ventilation units can be used by children over the age of 8 as well as persons with 

physical, sensory, or mental disabilities or lack of experience and knowledge, if they are supervised or instructed with 

regard to the safe use of the unit and they understand the resulting risks. Children must not play with the unit. 

Cleaning or user maintenance must not be carried out by unsupervised children.

CHAPTER 1

 

SAFETY

DANGER

 

NOTE

Summary of Contents for 8QRKDE

Page 1: ...t Kit Installation and Operating Instructions Airflow we reserve the right to make changes without prior notice External wall insulation vent kit 8QR KDE WHUQDO ZDOO LQVXODWLRQ YHQW NLW INSTALLATION AND OPERATING INSTRUCTIONS ...

Page 2: ... Contr oller kit Unoh ab CTRL kit flush Part No 90000994 Uno hab CTRL kit DIN rail Part No 90000995 Switching power supply Uno hab PSF Part No 90000996 included in Uno hab CTRL SET Uno hab PSD Part No 90000996 included in Uno hab CTRL DIN MAX 8 units Attention if necessary additional power supply required Output 12 V control line Output 12 V control line Input 230 V optional Additional power suppl...

Page 3: ...on of liability Page 5 2 1 Certificates Guidelines Page 5 2 2 Shipping Page 5 2 3 Receipt Page 5 2 4 Driving rain impermeability of the stainless steel wall grille Page 5 2 5 Limits of use stainless steel Page 5 CHAPTER 3 SCOPE OF DELIVERY Page 6 3 0 Scope of delivery Page 6 3 1 Dimensions Page 6 CHAPTER 4 POSITIONING ASSEMBLY Page 74 0 Installation overview soffit element Page 7 4 1 Positioning c...

Page 4: ...unit Depending on the overall ventilation requirement of the residential unit more than 2 units are normally installed and the individual volume flows are automatically adjusted by means of the central control unit The standard equipment allows installation and use in frost free rooms 5 C When operating under difficult conditions such as high levels of humidity long standstill periods excessive lo...

Page 5: ... in the original packaging 2 3 Receipt The shipment Uno hab Ext Wall Ins Vent Kit part number 90001002 must be checked for damage and correctness immediately upon delivery If there is any damage promptly report the damage with the assistance of the transport company If complaints are not made within the agreed period any claims could be lost 2 4 Driving rain impermeability of the stainless steel w...

Page 6: ...with labelling middle bottom ä EPP soffit channel ë EPP plaster frame ö Condensate discharge plate ü Wall grille incl seal for wall connection Å Fixing material 2x Insulation fixing 2x Stainless steel screw Ø 4 5 x 50 mm 4x Stainless steel screw Ø 5 x 100 mm 4x Stainless steel screw Ø 6 4 mm î Protective cover 2x for inside and outside Ø EPP fixing wedges 3 1 Dimensions fig 1 CHAPTER 3 SCOPE OF DE...

Page 7: ...rail ù Immersion depth of the wall installation sleeve in the soffit element Length 20 mm m NOTE The wall installation sleeve must not be cut off flush with the wall on the outside ä Soffit channel feet Max 40 mm Min 0 mm The soffit channel feet determine how far it sits from the uncovered wall The height of the feet and the height of the soffit channel of 100 mm corresponds to the min insulation ...

Page 8: ... with gradient to outside is required for the unit installation or Ø 172 mm horizontal with condensate wedge Include the empty conduit for the electr control cable in the installation wall NOTE The empty conduit must be placed below the unit installation position 1 Determine the position of the core drilling hole for the soffit element see Fig 6 2 Execute core drilling 3 Provide empty conduit for ...

Page 9: ...ll annular gap inside and outside with non pressurised installation foam Fig 9 10 9 After a sufficient drying time remove the protruding fixing wedges and excess installation foam If necessary remove EPP material lower front wedge and any installation foam residue for cable entry Fig 9 10 Create diffusion tight seal on annular gap Fig 10 11 Place protective cover on the wall installation sleeve In...

Page 10: ...ore drilling points for the soffit channel and remove the soffit channel 6 Drill the drilling holes and insert dowels not included 7 Connect soffit channel to the wall sleeve and screw in Fig 13 washers and screws are included 8 Apply thin glue sealing beads to the plaster frame Fig 14 9 Connect plaster frame to the soffit element and screw in with the enclosed insulation fixings Fig 14 15 10 Back...

Page 11: ...thout prior notice 11 Attach surrounding insulation panels Fig 16 12 Attach any plaster corner rails 13 Plaster the soffit channel and plaster frame 14 Remove any protruding plaster frame with multitool Fig 17 15 Insert condensate pan Fig 18 16 Mount wall grille Fig 19 The screws are included Fig 18 Fig 19 Fig 16 Fig 17 ...

Page 12: ...g periods condensation can form in the heat accumulator due to the process of heat recovery The condensation water must be able to drain from the unit A condensate drain gradient of 1 2 is ensured during installation by the EPP front wedge which is pre mounted to the wall installation sleeve TheprotrusionofthecondensatedraininthelowerEPPhalfshellallowsfreecondensatedrainageinthesoffitchannel from ...

Page 13: ...Uno hab Ext Wall Ins Vent Kit Installation and Operating Instructions 13 Airflow we reserve the right to make changes without prior notice Notes ...

Page 14: ...Uno hab Ext Wall Ins Vent Kit Installation and Operating Instructions 14 Airflow we reserve the right to make changes without prior notice Notes ...

Page 15: ...Uno hab Ext Wall Ins Vent Kit Installation and Operating Instructions 15 Airflow we reserve the right to make changes without prior notice Notes ...

Page 16: ...cations without prior notice All orders are accepted subject to our conditions of sale which are available on request Certificate No EMS 569454 BS EN 1SO 14001 2015 Certificate No FM 00152 BS EN 1SO 9001 2015 Airflow Developments Limited Aidelle House Lancaster Road Cressex Business Park High Wycombe Buckinghamshire United Kingdom HP12 3QP Call 01494 525252 Visit airflow com 80000782 Issue 2 09 20...

Reviews: