background image

Page 1

MODEL   QTN130LE

WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-

JURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 

power from being switched on accidentally. When the service 

disconnecting  means  cannot  be  locked,  securely  fasten  a 

prominent warning device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by a

qualified person(s) in accordance with all applicable codes

and standards, including fire-rated construction codes and

standards.

4.  Sufficient air is needed for proper combustion and exhausting 

of  gases  through the  flue  (chimney)  of  fuel  burning  equip-

ment to prevent backdrafting. Follow the heating equipment 

manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), 

and the American Society for Heating, Refrigeration and Air 

Conditioning Engineers (ASHRAE), and the local code authori-

ties.

5.  When  cutting  or  drilling  into  wall  or  ceiling,  do  not  damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  Acceptable for use over a tub or shower when connected to 

a GFCI (Ground Fault Circuit Interrupter) - protected branch 

circuit.

8.  This unit must be grounded.

CAUTION  

1.  For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2.  This product is designed for installation in ceilings up to a

12/12 pitch (45 degree angle). Duct connector must point up.

DO NOT MOUNT THIS PRODUCT IN A WALL.

3.  To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off power 

unit.

4.  Please read specification label on product for further informa-

tion and requirements.

MODEL QTN130LE
FAN / LIGHT / NIGHT LIGHT

READ AND SAVE THESE INSTRUCTIONS

WARRANTY

Installer: Leave this manual with 
the homeowner.

OPERATION

The fan, light, and night light can be operated separately. Use a 

3-function wall control. Do not use a dimmer switch to operate 

the light. See “Connect Wiring” for details.

CLEANING & MAINTENANCE

For quiet and efficient operation, long life, and attractive appear-

ance - lower or remove grille and vacuum interior of unit with the 

dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the 

motor bearings are making excessive or unusual noises, replace 

the blower assembly (includes motor and impeller).

Register your product online at: www.nutone.com/register

NUTONE THREE YEAR LIMITED WARRANTY

NuTone warrants to the original consumer purchaser of its products that such 

products will be free from defects in materials or workmanship for a period 

of three years from the date of original purchase. THERE ARE NO OTHER 

WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED 

TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR 

A PARTICULAR PURPOSE.
During this three-year period, NuTone will, at its option, repair or replace, 

without charge, any product or part which is found to be defective under 

normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP START-

ERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, 

DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR 

DUCTING. This warranty does not cover (a) normal maintenance and service 

or (b) any products or parts which have been subject to misuse, negligence, 

accident,  improper  maintenance  or  repair  (other  than  by  NuTone),  faulty 

installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the three-year period as 

specified for the express warranty. Some states do not allow limitation on how 

long an implied warranty lasts, so the above limitation may not apply to you.
NUTONE’S  OBLIGATION TO  REPAIR  OR  REPLACE, AT  BROAN-NU-

TONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE 

REMEDY UNDER THIS WARRANTY. NUTONE SHALL NOT BE LIABLE 

FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING 

OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. 

Some states do not allow the exclusion or limitation of incidental or conse-

quential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other 

rights,  which  vary  from  state  to  state. This  warranty  supersedes  all  prior 

warranties.
To qualify for warranty service, you must (a) notify NuTone at the address or 

telephone number below, (b) give the model number and part identification 

and (c) describe the nature of any defect in the product or part. At the time 

of requesting warranty service, you must present evidence of the original 

purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 

www.broan.com    800-558-1711

Summary of Contents for QTN130LE

Page 1: ... attractive appear ance lower or remove grille and vacuum interior of unit with the dusting brush attachment The motor is permanently lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the blower assembly includes motor and impeller Register your product online at www nutone com register NUTONE THREE YEAR LIMITED WARRANTY NuTone warrants to the o...

Page 2: ... damper to reduce backdrafts Plan to supply the unit with proper line voltage and appropriate power cable ROOF CAP WALL CAP Purchase separately INSULATION Can be placed around and over fan housing FAN HOUSING 6 IN OR 4 IN ROUND ELBOW S 6 IN OR 4 IN ROUND DUCT TYPICAL INSTALLATIONS Housing mounted to I joists Use I joist spacer block provided Housing mounted to joists Housing mounted to truss To mo...

Page 3: ... to I JOIST shown requires use of SPACERS included between the highest hole of each mounting flange and the I joist SPACER use for mounting to I Joist I JOIST INSTALL GRILLE 6 Finish ceiling Install ceiling material Cut out around housing 7 Attach grille to housing Squeeze grille springs and insert them into tabs on each side of housing 3 Attach damper duct connector Snap damper duct connector ont...

Page 4: ...gle TAB on the motor plate located next to the receptacle Push up near motor plate tab while pushing out on side of housing Or insert a straight blade screwdriver into slot in housing next to tab and twist screwdriver Not included purchase separately Order service parts by Part No not by Key No 9 Remove light lens Carefully insert a small flat blade screwdriver between grille and lens Pry lens out...

Page 5: ...onar la luz MODELO QTN130LE VENTILADOR LÁMPARA LÁMPARA DE NOCHE LIMPIEZA Y MANTENIMIENTO Para lograr un funcionamiento silencioso y eficiente como también larga vida y una apariencia atractiva baje o retire la rejilla y aspire el interior de la unidad con el accesorio del cepillo para sacudir polvo El motor está permanentemente lubricado y nunca necesitará aceite Si los cojinetes del motor están h...

Page 6: ...la unidad con el voltaje de línea y el cable eléctrico apro piados CUBIERTA DE VENTILADOR Se compran por separado TAPA DE PARED TAPA DE TECHO AISLAMIENTO Puede ser colo cado alrededor y sobre de la cubierta del ventilador CODO REDONDO DE 6 O 4 PULG CONDUCTO REDONDO DE 6 O 4 PULG INSTALACIONES TÍPICAS Montaje de cubierta en viguetas I Utilice un taco separador de viguetas I suministrado Montaje de ...

Page 7: ...ueta a través de los orifi cios más bajos de cada brida de montaje y seguidamente a través de los más altos NOTA El montaje a la VIGUETA I mostrada requiere utilizar SEPARADORES incluidos entre el orificio más alto de cada brida de montaje y la vigueta I 1 Doble las lengüetas de la cubierta Con un alicate doble las LENGÜETAS de la cubierta a 90 SEPARADOR se usa para el montaje a la vigueta I VIGUE...

Page 8: ...la clave 8 Empuje la rejilla contra el cielo raso 10 Instale las bombillas Compre dos 2 lámparas fluorescentes tipo GU24 de 18 W máx con una longitud total máxima de 3 9 pulg 100 mm como se muestra a continuación Compre una bombilla incandescente para lámpara de noche tipo C7 de 4 W máx Introduzca la lámpara y el bombillo en sus receptáculos Vuelva a colocar la lente 9 Saque la lente de la lámpara...

Reviews: