ECOFEL BOILER SERVICE MANUAL
9. Control
Panel:
- 15 -
Revision Date: 29 February 2008, Rev. No: 0
Item Nr.
Symbol
Function Description
Explanation
1
Program timer (Optional)
Used for daily or weekly programming of the operation time of the
boiler.
2
Thermo-manometer
Indicates heater outlet water temperature and closed circuit water
pressure.
It should be around 1.5 bars.
3
Usage water temperature
adjustment button
Allows the adjustment of usage water temperature to the desired
value between 35-55ºC.
Usage water cancelled mode
When hot usage water is not required from the boiler, hot usage
water adjustment button is turned to this symbol. No hot water will
be produced even if the hot water tap is turned on.
Exhaust gas emission
measurement function
This function is used by the authorized service when measuring
the exhaust gas emission values. When the usage water temperature
adjustment button is turned to this symbol, the boiler will operate
at maximum power.
4
Green led indicating that usage
water is operating
When the boiler is in summer mode, this led is on continuously.
When the tap is turned on, the led starts to blink indicating that
the boiler is operating in the hot usage water mode.
5
Red led indicating the failures
during operation
In any failure in the boiler due to any reason, this led lights and
warns the user. The boiler shall be restarted by turning the heater
temperature adjustment button to Off and then readjusting the
desired temperature.
6
Green led indicating that
heater mode is operating
When the boiler is in winter mode, this led lights continuously. If
the boiler starts operating to heat the house, the led will blink to
indicate that the boiler is operating in the heater mode.
7
Heater temperature
adjustment button
Allows the adjustment of heater water temperature to the desired
value between 35-80ºC. In winter mode the boiler will perform
both heating and hot usage water functions.
Summer mode
In summer mode the boiler will perform only hot usage water
function.
Standby
OFF
Reset mode
The boiler is off in standby mode. In this mode only frost protection
ant pump anti-blockage functions are active.