B. Power Failure:
Display: “POWER OFF”
The
Power Off
fault is displayed when the main power
supply drops to 65% or less of nominal voltage. The
pump will automatically shut off the valves and the
motor, and display “Power Off” on the LCD.
NOTE: “Power Off” is also displayed for several
seconds after the unit is disconnected from the
electrical supply.
C. Button Fault:
Display: “Button Fault”
The
Button Fault
is displayed when the micro processor
detects any button press during the boot sequence or
if the shroud on/off button is held in for more than 3
seconds.
D. Motor Overload:
Display: “MTR OVLD”
The
Motor Overload
fault is displayed when the electric
current drawn by the motor exceeds the pre-set limit of
the internal circuit breaker. The internal circuit breaker
will automatically reset once the condition has been
corrected; however, the operator must clear the fault and
then press the motor on/off button to restart the motor.
E. Oil Temperature
(requires optional float/temperature
switch)
Display: “OIL TEMP”
The
Oil Temperature
fault is displayed when the
temperature of the oil inside the reservoir exceeds 175°
F (80° C).