Page 10
PL19-6000EN
05/15/2015
F. Oil Level
(requires optional float/temperature switch)
Display: “OIL LEVEL”
The
Oil Level
fault is displayed when the oil level inside
the reservoir drops below 1.3” (34mm) from bottom.
Warning Conditions:
All warnings notify the operator of an abnormal operating
condition, however, allow pump to continue operating.
Warnings will automatically clear once the issue has
been resolved.
A. Low Voltage:
Display: “LOW VOLT”
Low Voltage
A
Low Voltage
condition is defined as an operating
condition when the main power supply is at or below
80% of nominal voltage. While running the pump under
this condition, the “Low Voltage” signal will flash on the
LCD and the Low Voltage hours will be counted and
stored on the control board. Normal pump operation is
still provided.
For optimized pump performance it is
recommended NOT to run the pump at a
Low Voltage condition.
Airetool
®
General Instructions
Figure 12: Oil Level
Figure 13: Low Voltage