3.1 CONFIGURE FAN ON TIME

Press the Mode Key once to enter the Menu Mode. FAN ON will flash on the display.

1.  Use the Increase or Decrease Keys to change the FAN ON time from 1 - 199 minutes or to select unlimited ON 

time (UN).  UN allows the fan to operate continuously.

3.2 CONFIGURE FAN OFF TIME

1.  Press the Mode Key again to set the FAN OFF time.  FAN OFF will flash on the display.

2.  Use the Increase or Decrease Keys to change the FAN OFF time or to select unlimited OFF time (UN). This will 

turn off the AirCycler®. This will also keep the AirCycler® off even after power is lost.*

*The AirCycler® retains settings even after power is lost.

NOTE:

 In humid climates, the FAN OFF time should be at least 6 minutes. This allows moisture on the AC coil to dry 

preventing condensation in cold supply ducts.

3.3 CONFIGURE VENT ON TIME

1.  Press the Mode Key. VENT ON will flash. 

2.  Use the Increase or Decrease Keys to change the VENT ON time.

3.4 CONFIGURE VENT OFF TIME

1.  Press the Mode Key. VENT OFF will flash.

2.  Use the Increase or Decrease Keys to change the VENT OFF time.

3.5 SAVE SETTINGS

After configuring the AirCycler®, press the Mode Key again to save settings and to enter into Operating Mode.

Increase 

Button

Mode Button

On/Off

Decrease

Button

Figure 5

Summary of Contents for FRV

Page 1: ...Ventilation Products AirCycler FRV Installation User s Guide VENTILATION MADE BREEZY a breeze to install a breeze to use ...

Page 2: ...er the existing HVAC system can be used to provide venti lation The AirCycler enables this ventilation system to work properly The AirCycler FRV adds an output to operate a motorized outside damper that limits excessive ventilation Motorized Damper sold separately see AirCycler VS ACVS 06 for more information IMPORTANT If the AirCycler was installed in your home as a ventilation controller DO NOT ...

Page 3: ... C W Y from the air handler to the thermostat can run parallel with the wiring from the AirCycler to the air handler The fan wire G needs to be interrupted by the AirCycler Some thermostats do not require a C connection The AirCycler requires a C for power which must be wired to the furnace KEY Y Cooling R 24 VAC Power W Heating Gt Fan to Thermostat Gf Fan to Furnace C Common V Vent Air Handler Ai...

Page 4: ...ole in mounting base 5 Adjust length and routing of each wire to reach proper terminal and connector block on mounting base with 1 4 in of extra wire Strip only 1 4 in of insulation from each wire to prevent adjacent wires from shorting together when connected 6 Connect wires to proper terminals of the con nector block Figure 3 Both R and C must be connected for proper operation 7 Improper wiring ...

Page 5: ...rCycler This will also keep the AirCycler off even after power is lost The AirCycler retains settings even after power is lost NOTE In humid climates the FAN OFF time should be at least 6 minutes This allows moisture on the AC coil to dry preventing condensation in cold supply ducts 3 3 CONFIGURE VENT ON TIME 1 Press the Mode Key VENT ON will flash 2 Use the Increase or Decrease Keys to change the...

Page 6: ... and VENT OFF times will be reset to programmed values 4 1 POWERING OFF Warning It is not recommended to turn off the AirCycler if the unit is used as a ventilation controller The AirCycler can be turned off during extended vacation periods or when the windows are open It is very important to turn the Air Cycler back on after those periods 1 In normal Operating Mode Press and hold the Mode Key for...

Page 7: ...irmly seated in the base Problem AirCycler FR V turns furnace fan on and off but the motorized damper does not cycle Solution Check 1 Confirm that the AirCycler is providing a 24 VAC signal to the motorized damper 2 Verify that 24 VAC motorized damper is operational by powering directly with a 24 VAC signal 3 Check continuity in the wiring between the damper and the AirCycler Problem A C turns on ...