Remote Controller Specifications
Strona 54
Read the safety precautions carefully before installing the unit.
Stated below are important safety issues that must be obeyed.
Means improper handling may lead to personal death or severe injury.
Means improper handling may lead to personal injury or property loss.
WARNING
CAUTION
Please entrust the distributor or professionals to install the unit.
Installation by other persons may lead to imperfect installation, lectric shock or fire.
Adhere to this installation manual.
Imporper installation may lead to electric shock or fire.
Reinstallation must be performed by professionals.
Improper installation may lead to electric shock or fire.
WARNING
Do not install the unit in a place vulnerable to leakage of flammable gases.Once
flammable gases are leaked and left around the wire controller, fire may occure.
Do not operate with wet hands or let water enter the wire controller. Otherwise,
electric shock may occur.
The wiring should adapt to the wire controller current. Otherwise, electric leakage or
heating may occur and result in fire.
The specified cables shall be applied in the wiring. No external force may be applied
to the terminal. Otherwise, wire cut and heating may occur and result in fire.
NOTE
Do not uninstall the unit randomly.
Random uninstalling may lead to abnormal operation, heating or fire of the air condition.
1
2
3
4
1.
SAFETY PRECAUTION
Strona 55
Precaution of install the wire controller
1. This manual provides the installation method of wire controller. Please refer to the
wiring diagram of this installation manual to wire the wire controller with indoor unit.
2. The wire controller working in low voltage loop circuit. Forbid to directly contact the
cable of 220Vcommercial electricity or of 380V high voltage, and don’t wire this kind
of wire in the said loop; wiring clearance between configured tubes should at the
range of 300~500 or above.
3. The Shielded wire of the wire controller must be grounded reliable.
4. Upon finish the wire controller connection, do not employed tramegger to detect the
insulation.
5. The connective cable of wire controller should not be longer than 20 meters.
2. INSTALLATION ACCESSORY
Don’t install at the place where cover with heavy oil, vapor or sulfureted gas,
otherwise, this product would be deformed that would lead to system malfunction.
Select the installation location
Preparation before installation
1. Please confirm that all the following parts you have been supply.
2. Prepare the following assemblies on the site.
The connective wires group-1
1
2
3
4
5
3
2
M4X20 (For Mounting on the Wall)
M4X25 (For Mounting on switch box)
1
2
1
6
7
3
2
1
No.
Name
Qty.
Remarks
Wire controller
Installation and owner’s manual
For Mounting on the Wall
Switch box
Wiring Tube(Insulating
Sleeve and Tightening
Screw)
Qty.(embeded
into wall)
Plastic screw bars
Screws
Wall plugs
For fixing on switch box
No.
Name
Remarks
Specification
(only for reference)
Screws
1
1
1
Optional
Connect to mainboard
The connective wires group-2
8
1
Battery
9
1
Summary of Contents for MDV DCTB-24R32IVT IN