3. Introduction
• Models BCL (90, 100, 120, 130, 145) S
BCL-S
models are rear breech oil fired forced air lowboy
furnaces with output capacity range of 90,000 to 141,000
Btu/hr.
• Models BFL (90, 100, 120, 130, 145)
BFL models are front breech oil fired forced air lowboy
furnaces with output capacity range of 88,000 to 139,000
Btu/hr.
• Models BCL (170-2, 190, 200, 225)
BCL models are rear breech high capacity oil fired
forced air lowboy furnaces with output capacity
range of 177,000 to 237,000 Btu/hr. Shipped in two
pieces; furnace section and blower section, which are
assembled together at the installation site.
Furnace models are either factory equipped for chimney
venting or factory equipped for direct venting.
Chimney vent models and direct vent models are not
field convertible. Direct vent installation instructions are
included with the direct vent models.
Installation shall conform to requirements of
authority having jurisdiction or in absence of such
requirements:
• Canada - CAN/CSA - B139, Installation Code for Oil-
Burning Equipment.
• United States - National Electrical Code, NFPA31,
Standard for the Installation of Oil-Burning Equipment.
Models are CSA listed, (NRTL/C) for use with No. 1
(Stove) and No. 2 (Furnace) Oil.
Refer to tables in Appendix A for performance data.
4. Heat Loss
Maximum hourly heat loss for each heated space shall be
calculated in accordance with the procedures described in
the manuals of:
• Canada - The Heating, Refrigeration and Air
Conditioning Institute of Canada (HRAI), or by other
means prescribed, or approved by the local authority
having jurisdiction.
• United States - Manual J. titled, "Load Calculation"
published by the Air Conditioning Contractors of
America, describes a suitable procedure for calculating
maximum hourly heat loss.
1. General
Furnace installation shall be completed by qualified agency.
WARNING
Fire, explosion, asphyxiation and electrical shock
hazard. Improper installation could result in death
or serious injury. Read this manual and understand
all requirements before beginning installation.
!
NOTICE
Used to address practices not related to personal
injury.
CAUTION
Indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.
!
WARNING
Indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
!
DANGER
Indicates a hazardous situation which, if not
avoided, WILL result in death or serious injury
!
This is the safety alert symbol. Symbol alerts you to
potential personal injury hazards. Obey all safety messages
following this symbol to avoid possible injury or death.
Become familiar with symbols identifying
potential hazards.
2. Safety Symbols
WARNING
Fire, burn, asphyxiation hazard. Do not use
gasoline, crank case oil, or any oil containing
gasoline. Failure to follow these instructions could
result in death or serious injury.
!