13
PN 28141 REV. K [10/30/2018]
Check out and adjustments
BCL and BFL furnaces may be used with following oil burners.
Beckett AF, Beckett NX and Riello 40F oil burners are for applications using indoor air for combustion only.
Sidewall venting applications utilizing outdoor air for combustion, use Beckett AFII oil burners only.
Table A-1 Beckett AF and Beckett NX Oil Burner Set-Up
Beckett AF and Beckett NX Series Oil Burners
(For use with chimney vented units)
Furnace
Model
Burner
Model
Nozzle
Pump
Pressure
Flow Rate
Head
Static
Plate
BCL90S2
BCL90ST2
AF65XN
0.75 / 80°A
100
psig
0.75
usgph
F3
2-
¾
in.
BCL100S2
BCL100ST2
AF65XN
0.85 / 80°A
100
psig
0.85
usgph
F3
2-
¾
in.
BCL120S2
BCL120ST2
AF65XN
1.00 / 80°A
100
psig
1.00
usgph
F3
2-
¾
in.
BFL90-2
BFL90T2
AF65XN
0.75 / 80°A
100
psig
0.75
usgph
F3
2-
¾
in.
BFL100-2
BFL90T2
AF65XN
0.85 / 80°A
100
psig
0.85
usgph
F3
2-
¾
in.
BFL120-2
BFL120T2
AF65XN
1.00 / 80°A
100
psig
1.00
usgph
F3
2-
¾
in.
BCL130S2
BCL130ST2
AF65YB
1.10 / 70°A
100
psig
1.10
usgph
F6
2-
¾
in.
BCL145S2
BCL145ST2
AF65YB
1.20 / 60°A
100
psig
1.20
usgph
F6
2-
¾
in.
BFL130-2
1
BFL130T2
1
AF65YB
1.10 / 70°A
100
psig
1.10
usgph
F6
2-
¾
in.
BFL145-2
1
BFL145T2
1
AF65YB
1.20 / 60°A
100
psig
1.20
usgph
F6
2-
¾
in.
BFL130NX2
BFL130TNX2
NX70LFHS
1.00 / 60°W
140 PSIG
1.10 USGPH
6-SLOT
N/A
BFL145NX2
BFL145TNX2
NX70LFHS
1.10 / 60°W
140 PSIG
1.20 USGPH
6-SLOT
N/A
BCL170-2
AF81WF
1.50 / 70°B
100
psig
1.50
usgph
F16
2-
¾
in.
BCL190
AF81WF
1.65 / 70°B
100
psig
1.65
usgph
F16
2-
¾
in.
BCL200
AF81WF
1.75 / 70°B
100
psig
1.75
usgph
F16
2-
¾
in.
BCL225
AF81WF
2.00 / 70°B
100
psig
2.00
usgph
F16
2-
¾
in.
1
These models do not meet U.S. Government requirements for minimum AFUE efficiency. They are
intended for Canada only, and only until Amendment 14 to Canada's
Energy Efficiency Regulations
take effect. After that date they will no longer meet Canadian Government requirements for minimum
efficiency.
APPENDIX A - CHECK OUT AND ADJUSTMENTS
Summary of Contents for BCL-190