Aircalo ACGC 20 Technical Notice And Instructions For Montage Download Page 5

TYPES 

ACG16H  ACG20H  ACG26H  ACG28H  ACG35H  ACG36H  ACG45H  ACG55H  ACG75H  ACG95H 

Calorific output 

kW 

16 

21 

26 

28 

35 

36 

45 

55 

71 

92 

Usable power  

kW 

14.5 

19.5 

23.5 

25,5 

31,5 

32.5 

40,5 

50 

64,4 

84 

Efficiency 

 % 

 > 91 

>91 

>91 

> 91 

> 91 

>91 

> 91 

> 91 

> 91 

> 91 

No of fans 

Rotation speed 

Rpm   1 400 

900 

900 

900 

900 

900 

900 

900 

900 

900 

Air flow at 15 °C  
Air flow at 50 °C 

m

3

/h 

1 350 
1 500  

1 450 
1 625  

2 000  
2 250 

2 050  
2 300 

2 900   
3 250 

2 900  3 

250 

4 000  
4 450 

4 900  
5 500 

5 800  
6 500 

8 000  
8 950 

Delta T° of air  

°C 

32 

40 

35 

36 

32 

33 

30 

 30 

32 

31 

Reach of air jet  

12 

12 

16 

16 

23 

23 

26 

28 

30 

30 

Gas flow at 15°

    Natural          
G20  

 

20 

mbar 

25 

 

1.69 m

3

h  

1.88 m

3

 

2.22 m

3

h  

2.46 m

3

 

2.75 m

3

h  

3.06 m

3

 

2.96 m

3

h  

3.29 m

3

 

3.70 m

3

h  

4.11 m

3

 

3.81 m

3

h  

4.23 m

3

 

4.76 m

3

h  

5.28 m

3

 

5.82 m

3

h  

6.43 m

3

 

7.40 m

3

h  

8.22 m

3

 

10.0 

m

3

/ h  

11.1 

Smoke diameter   mm 

80 / 125  80 / 125  80 / 125  80 / 125  80 / 125  80 / 125 

100 

130 

130 

130 

Air inlet 

mm 

100 

130 

130 

130 

Supply voltage  

Electrical power   VA 

290 

300 

310 

310 

320 

320 

350 

500 

580 

750 

Weight  

kg 

54 

81 

82 

82 

85 

85 

105 

125 

152 

194 

Noise level  
(fan) 

dBa 

37 

39 

40 

40 

41 

41 

46 

51 

52 

49 

Mono-phase 230 Volts / 50 Hz - IP42   

2-1 Performance of ACGH helical gas unit heaters

 

Overall dimensions of ACGH models 

 

Axial Fan. ACGH Model  
 

The ACGH unit heaters are equipped with  
an axial fan. 

 

They are intended for direct blowing and  
are equipped, as standard, with a double 
deflection grille.  

 

Ø F  Ø Air  Ø G 

ACG16H 

810 

780 

356 

80 / 125 

1/2 

ACG28H 

1 040  820 

460 

80 / 125 

1/2 

ACG35H 

1 040  820 

510 

1/2 

ACG45H 

1 040  820 

570 

100 

100 

1/2 

ACG55H 

1 040  840 

700 

130 

130 

1/2 

ACG75H 

1 120  840 

820 

130 

130 

3/4 

ACG95H 

1 120  840  1075  130 

130 

3/4 

80 / 125 

ACG20H 

1 040  800 

460 

80 / 125 

1/2 

ACG26H 

810 

820 

460 

80 / 125 

1/2 

ACG36H 

810 

820 

570 

80 / 125 

1/2 

2- TECHNICAL SPECIFICATIONS OF ACG UNIT HEATERS 

Connection for 20/28/35 

Connection for 45/55/75/95 

Smoke 

Gas 

Smoke 

Gas 

Air 

Air 

Summary of Contents for ACGC 20

Page 1: ...1 DTC AT 13 135 FR GAZ FIRED AIR HEATERS TECHNICAL NOTICE AND INSTRUCTIONS FOR MONTAGE ACGH 16 20 28 35 45 55 75 95 ACGC 20 28 35 45 55 75 95 ACGV 26 28 36 45 55 75 95 1312BO3933...

Page 2: ...16 20 26 28 35 36 45 55 10 3 2 Rotation console for IPN adjustable for ACGH 16 20 26 28 35 36 45 55 10 3 3 Adjustable wall mounted console for ACGH75 95 11 3 4 Adjustable wall mounted console for ACGC...

Page 3: ...ich accompany the product at its shipment can be considered as contractual keep the instructions carefully near the device 1 1 Description of the device Operation The ACG gas unit heater is a generato...

Page 4: ...on which is unsuitable or not in conformity with current standards Only defects in manufacture or raw materials are concerned The guarantee is limited to the replacement of parts which are found to be...

Page 5: ...er mm 80 125 80 125 80 125 80 125 80 125 80 125 100 130 130 130 Air inlet mm 100 130 130 130 Supply voltage Electrical power VA 290 300 310 310 320 320 350 500 580 750 Weight kg 54 81 82 82 85 85 105...

Page 6: ...V Calorific output kW 26 36 45 55 71 92 Usable power kW 23 5 32 5 40 5 50 64 4 84 Efficiency 91 91 91 91 91 91 No of fans 1 1 1 1 1 2 Rotation speed Rpm 900 900 900 1400 1400 900 Air flow at 15 C Air...

Page 7: ...128 490 217 677 100 100 1 2 The ACGV models are retained at their upper part by four tightened M8 nuts Blowing is vertical towards the ground and the installation height must not be lower or higher th...

Page 8: ...4 76 m3 h 5 28 m3 h 3 51 kg h 5 82 m3 h 6 43 m3 h 4 30 kg h 7 40 m3 h 8 22 m3 h 5 46 kg h Smoke diameter mm 80 125 80 125 80 125 100 130 130 Air input diameter mm 100 130 130 Supply voltage Electrical...

Page 9: ...w pressure curves with filter consult us for this application Maximum dimension of the ACGC models and optional accessories A A1 A3 B B1 H L L1 L2 F Air AT 20 1040 750 780 480 440 460 356 381 310 80 1...

Page 10: ...ke sure of the strength of the bracket C ACG16 H ACG20H ACG26H ACG28H ACG35H ACG36H ACG45H ACG55H Connection B22 C32 B22 C32 B22 C32 B22 C32 B22 C32 B22 C32 B22 C32 B22 C32 Dim A mm 110 160 162 160 18...

Page 11: ...CG35C ACG45C ACG55C ACG75C Connection B22 C32 B22 C32 B22 C32 B22 C32 B22 C32 B22 C32 Dim A mm 115 125 115 125 115 125 125 190 135 205 135 205 Dim B mm 205 205 230 245 295 410 Dim C mm 585 585 585 585...

Page 12: ...cs of the gas heaters ACGH ACGC 4 ELECTRICAL WIRING 4 2 Electrical schematics of centrifugal gas air heaters ACG75 Phase brown Neutral blue Earth green yellow Pilot black Phase brown Neutral blue Eart...

Page 13: ...Inspection box MVE Smoke extractor PA Burner air pressure switch SI Ionisation sensor EA Ignition electrode MOD Gas modulating valve 2 speed option EVG Gas solenoid valve TI Isolation transformer Und...

Page 14: ...orced ventilation and remote resetting Several models of thermostat 4 are available The use of these thermostats will provide you with supplementary functions such as remote resetting and forced venti...

Page 15: ...EG112 Individual controller without thermostat Ambient thermostat with on off fan switch and remote resetting Clock programmable ACG gas unit heaters are equipped as standard with a receiver which ena...

Page 16: ...h of 250 500 1000 mm 6 Concentric length of 500 1000 mm 7 Sealed elbow at 45 or 90 8 Concentric elbow at 45 or 90 9 Flat flashing 10 Tilted flashing with lead strip 4 6 9 10 5 3 Connecting to the unit...

Page 17: ...n air inlet and smoke evacuation are vertical through the roof to the outside of the building The connection is concentric in diameter 80 125 and is connected directly onto the unit heater The KC3280...

Page 18: ...total length of the circuit must not exceed 8 metres taking into account that an elbow of 90 or 45 corresponds to a length of 1 metre A double wall conduit must be provided if the part outside the bui...

Page 19: ...hanging the seals Item 4 and making sure concerning sealing The injectors must be installed dry 5 Reassemble the ramp and connect the gas line to the gas valve replacing the seal make sure during asse...

Page 20: ...lator pressure Gas ramp injectors Extractor washer Low speed High speed Low speed High speed Low speed High speed ACG16 6 mbar 9 mbar 4 x AL 1 90 40 7 mbar 12 mbar 4 x AL 1 90 40 13 mbar 25 mbar 4 x A...

Page 21: ...delivered with the device Tighten the union onto the network before connecting it to the unit heater Check that the gas supply circuit is correctly sealed upto the gas solenoid valve see schematic 8...

Page 22: ...22 ATE024 ATE022 ATE025 13 Inspectioni and safety box ATE318 ATE318 ATE318 ATE318 ATE318 ATE318 ATE318 14 Burner regulation airstat 65 C ATE146 ATE146 ATE146 ATE146 ATE146 ATE146 ATE146 15 Fan airstat...

Page 23: ...and clean them Injectors Clean the gas injectors Ionisation sensor and electrodes Check their condition change them if necessary Gas filter Disassemble the dirty cartridge and clean it with compresse...

Page 24: ...ing Check the pressure The device goes into safety position during operation red light comes on Gas supply interrupted Reset by pressing the red push button on the control box Cold air when starting I...