5– CONNECTING THE EVACUATION CONDUITS
5-1 Evacuation conduit accessories for ACG 20/28/35
5-2 Evacuation conduit accessories for ACG 45/55/75/95
2 Horizontal concentric cup with finishing
flap
3 Concentric roof cup
4 Chimney outlet ( moulding not supplied )
5 Sealed length of 250/500/1000 mm
6 Concentric length of 500/1000 mm
7 Sealed elbow at 45°
8 Sealed elbow at 90°
9 Flat flashing
10 Tilted flashing with lead strip
3
2
6
5
7
10
9
8
1
1 Concentric telescopic extension
2 Concentric horizontal cup with finishing
flap
3 Concentric roof cup
4 Chimney outlet with moulding
5 Sealed length of 250/500/1000 mm
6 Concentric length of 500/1000 mm
7 Sealed elbow at 45° or 90°
8 Concentric elbow at 45° or 90°
9 Flat flashing
10 Tilted flashing with lead strip
4
6
9
10
5-3 Connecting to the unit heater
Correct assembly
Incorrect assembly
- Assembly of the smoke conduits must be carried out using a slope opposed to the device,
α
= 2°
minimum.
- The assembly of the conduits must be carried out so that no water can penetrate into the device,
due to the electrical risk. For this purpose, please use a purge T-piece and a condensate recoverer,
- Make sure not to damage the connector seals when assembling the conduits onto the device,
check the sealing after assembly.
- For greater lengths, it is essential to provide a condensate recoverer; this also applies to
assemblies using cups.
2
8
7
5
3
4
α
= 2°