EN
BATTERY REPLACEMENT
Replace the battery when the display becomes weak or the alarm tone declines.
Open the battery compartment and insert a new battery 1,5 V AA, ensure that the battery polaritiy is
correct.
Close the battery compartment again.
TROUBLESHOOTING
No display on the device:
Ensure that the battery polarity is correct
Use a pin to press the RESET button
Change the battery
Incorrect indication:
Change the battery
If device fails to work despite these measures contact the supplier from whom you purchased it.
WASTE DISPOSAL
This product has been manufactured using high-grade materials and components which can be
recycled and reused.
Never dispose of empty batteries and rechargeable batteries in household waste.
As a consumer, you are legally required to take them to your retail store or to an appropriate
collection site depending on national or local regulations in order to protect the environment.
The symbols for the heavy metals contained are:
Cd=cadmium, Hg=mercury, Pb=lead
This instrument is labeled in accordance with the EU Waste Electrical and Electronic Equipment
Directive (WEEE).
Please do not dispose of this instrument in household waste. The user is obligated to take end-
of-life devices to a designated collection point for the disposal of electrical and electronic
equipment, in order to ensure environmentally-compatible disposal.
SPECIFICATIONS
Power consumption:
Battery 1 x 1.5 V AA
Measuring range temperature:
0°C…+50°C (+32°F…+122°F) °C/°F-reversible
Measuring range humidity:
20...90 % rH
Display shows LL/HH:
Measuring is out of the range
Housing dimension:
94 x 37 x 94 mm
Weight:
95 g (instrument only)
Manufacturer: Bibetus, s.r.o., Loosova 1, Brno 638 00
No part of this manual may be reproduced without written consent of manufacturer. The technical data are
correct at the time of going to print and may change without prior notice. The latest technical data and
information about your product can be found by entering your product number on our homepage.
10/2015
Page 4 / 4