background image

1

EN

airwash and humidify the size equivalent to small room.

5) Sleeping Operation : Runs quietly. Stops when humidity exceeds 60% and restarts when it reaches under 
60%.The brightness of display window becomes half of normal condition not to disturb sleeping.

Button 3: BSS filter indicator

When the life of the disinfection system has been expired (about 1 year), an indicator will appear.
After replacing the BSS, please push operation selection button and hold for 3 seconds. The product will
initialize.

Button 4: Out of water indicator

When the water runs out, the product stops working and displays the icon on LCD panel. Operate after filling
up water. 

Button 5: Switch on/off plasma ion generator

Switch on/off plasma ion generator

Button 6: Plasma ion generator indicator

When indicaton light on, function is active. 

The brightness of the LCD window will be reduced to half when one minute would have passed after the last
operation was selected

 3.5  Resupplying of water

        

            

For water resupplying, just fill it with insufficient amount (1) 
until the sixth day but on the seventh day, remove the water 
remaining in the cistern and after cleaning, resupply it again.

※ Even if the water in the cistern is somewhat contami-
nated,onlypurewaterishumidifiedsothereisno need to worry.
※ If you resupply the water regularly each day, it be-comes 
more convenient.

 3.6  Emptying of water

If the environment surrounding has excessive dust or odor or frequent ventilation cannot be done, 

you must empty out the water more frequently.

After opening the main body, if the water level (1) of the cistern is at a low level, you must empty 

out the cistern and resupply with fresh water.

※The remaining water has dust, foreign material, odor and others so by resupplying with fresh 

water, the air cleaning function is greatly improved.

 Fill the freshwater below the marked water level.

Page 10 of 17

Summary of Contents for AIRWASHER

Page 1: ...rate it and to get advice in the event of faults Following and respecting the instructions in your manual will prevent damage to your instrument and loss of your statutory rights arising from defects...

Page 2: ...al friendly material BSS BSS Bio Silver Stone non chemical material kills and eliminates various kinds of germs and viruses inside the water tank Germ killing by more than 99 99 3 Very easy for cleani...

Page 3: ...rseas uses when the voltage is different it many fail to work or fire may ensue Warning Please avoid exposure to direct light places of high heat or near heaters Change of color or form may occur in t...

Page 4: ...ution Don t use it close to other electric housing appliance Keep at least 30cm of distance from them to minimize harmful effect Warning Do not sit or step on the product The product may be broken and...

Page 5: ...rm water which is under 40 Warning Do not forcefully enter sticks or fingers into the intake or the exhaust or attempt to independently remodel or separate the product May lead to product malfunction...

Page 6: ...purpose without consultation The disinfectant material may affect the respiratory organs Warning Do not handle with force the disinfectant device BSS surface The content may damage Do not separate or...

Page 7: ...r cord is plugged in the socket Caution Clean or supply water after plugging out from the power 3 Correct Operation 3 1 Installation After moving to place of installation read the Safety Advices first...

Page 8: ...bout 12 month For repurchase of the part please consult the customer service center 6 Power cord Supplies Electricity to the Product 7 Upper cover The upper side is dried and the contaminated air is t...

Page 9: ...se insert the connector to the product first and then insert the plug to the wall socket When disconnecting the power cord please pull out the plug from the wall socket first and then separate the con...

Page 10: ...of the LCD window will be reduced to half when one minute would have passed after the last operation was selected 3 5 Resupplying of water For water resupplying just fill it with insufficient amount 1...

Page 11: ...duct might malfunction or you might get electrocuted It should be cleaning by a tightly squeezed wet towel for its interior and exterior Stop operations and remove the electrical line power cord from...

Page 12: ...is a danger of dropping it The product can smell if it has lot of dust having not cleaned for a while Although foreign materials on the cistern and the discs would not make them look good they do not...

Page 13: ...nd does not move If you use the Easy Kit Brush you can tighten the cap easily 3 9 Cleaning pre filter once a month Please clean as following if the air suction fan and its area are very dirty Caution...

Page 14: ...er part cover by pushing slightly in the four places until you hear the sound click 3 11 Cleaning Plasma ion generator The air blowing part would be cleaned periodically once in every year If the prod...

Page 15: ...mode the fan stops if the room humidity exceeds 60 6 Haven t you pressed stop button Please press the power button on the left Disks do not turn 1 For the upper part of the main frame and the lower p...

Page 16: ...ted so there is no need for any worry But please be sure to wash surely one time a week The color of the disinfectant device has changed This is due to the silver ionization of oxygen in the disinfect...

Page 17: ...ust not be disposed in the normal unsorted municipal waste stream Old appliances must be collected separately in order to optimize the recovery and recycling of the materials they contain and reduce t...

Reviews: