PRIOR TO USE 

PREPARATION 

Immediately upon receiving the MF600, examine the packaging for any damage that may have occurred 
during shipment. In the event of any damage please contact the supplier immediately. 

INSTALLATION 

This unit weighs approximately 60kg.  The unit must be installed on a suitable level floor or mount that is able 
to support its weight. Before installation, check that adequate space is available for replacement of filters. 

ELECTRICAL CONNECTIONS 

The unit is prewired to a standard 13a mains cable. This may be replaced if required by removing the cover of 
the control panel. 

Take care not to pinch the electrical cables. 

Switch on unit prior to final installation to check function. 

Page 

!

 of 

!

4

7

Summary of Contents for MF600

Page 1: ...AirBench MF600 Operation and Maintenance This Edition 6 September 2016 AirBench Ltd 14 Grange Farm Road Colchester CO2 8JW www airbench com 44 0 1206 791191 Page of 1 7 AIRBENCH LTD ...

Page 2: ...FOR USE 3 Prior to Use 4 PREPARATION 4 INSTALLATION 4 ELECTRICAL CONNECTIONS 4 Operation 5 PRINCIPLE OF OPERATION 5 CONTROLS 5 FILTER REPLACEMENT 5 LOG BOOK 5 FILTER ACCESS 6 FAULT FINDING 6 Support 6 DECLARATION OF CONFORMITY 7 Page of 2 7 ...

Page 3: ...e Always make sure that good access is provided for the maintenance of the MF600 The MF600 must not be used in an environment where there is a risk of explosion from dust or gases in explosive concentrations The MF600 must only be used for the designated application Contact us before change of use The MF600 must not be used without filters Always isolate the mains power before changing filters or ...

Page 4: ...kg The unit must be installed on a suitable level floor or mount that is able to support its weight Before installation check that adequate space is available for replacement of filters ELECTRICAL CONNECTIONS The unit is prewired to a standard 13a mains cable This may be replaced if required by removing the cover of the control panel Take care not to pinch the electrical cables Switch on unit prio...

Page 5: ...er on off 2 RED LIGHT Advises filter over pressure 3 WHITE LIGHT Power on FILTER REPLACEMENT When filter 1 is full it can be emptied Remove the filter from the housing and either vacuum gently or tip loose dust into a skip Wear appropriate PPE when performing filter maintenance Filter 2 must be replaced when full LOG BOOK A log book is supplied with this unit It should be used to record routine an...

Page 6: ...01206 791191 Fax 01206 791091 Web www airbench com Email sales airbench com Fault Remedy Lack of Suction Dirty filters see page 5 Motor does not operate Mains fuse tripped Fan discharge air is contaminated The filtration system is being by passed Check for damage or incorrectly fitted filter s and replace as appropriate Always isolate the mains power before changing filters or removing any compone...

Page 7: ...achines general requirements EN 60335 2 80 Safety requirements for electric fans and regulators We AIRBENCH Limited declare that MF600 when supplied as self contained equipment complies with the directives detailed above and therefore comply with requirements of the Low Voltage Directive Business Name AirBench Ltd 14 Grange Farm Road Colchester Essex CO2 8JW Responsible Person Simon Cook Descripti...