XT-400/800 Operating Instructions
6
All the remote buttons work the same as the
control panel buttons.
Hint: If you mount the unit at a high location you
can “bounce” the remote signal off the ceiling to
make the unit work.
The Remote Control Panel features five buttons
labeled FAN, FUNCTION, POWER, UP and
DOWN. Press the red POWER button to turn the unit on and off.
The
FUNCTION selector button
is used to program the fan speed, the ozone level
(ozone burst timer), program the countdown timer, or to turn the audible beep sound
on/off.
To Set Fan Speed:
Press the FUNCTION button until the orange FAN (F.) light is lit. Press the FAN button
to set the fan speed to low, medium, or high.
To Set the Ozone Level (O
3
):
Press the FUNCTION button until the green O
3
light is lit. Use the UP and DOWN
buttons to set the ozone level up or down from level 1 to level 10. This will burst the
ozone on for either 2, 5, 10, 15, 20, 25, 30, 40, 50, or 60 seconds per minute. Level 10
is 60 seconds per minute or continuous.
*The Power (P.) light is steady red when ozone is being produced, and
blinks red while counting down to the next ozone burst
. For example, if
the O3 setting is on 1, the Power (P.) light will be steady for 2 seconds
and blink for 58 seconds.
To Set the Countdown Timer (T.):
Press the FUNCTION button until the red TIMER (T.) light is lit. Use the UP and DOWN
buttons to set the timer for 10, 20, 30, 40, 50, 60, 70, 80, 90, or cn (continuous). If you
select cn (continuous), the unit will run continually and not shut off. All other selections
will run for the programmed time and then shut off.