background image

 

XT-400/800 Ozone Generator 

Operating Instructions 

 

 

 
 

Air-Zone Inc. 

1980 Northgate Commerce Parkway; Suite 6C 

Suffolk, VA  23435 

757-465-1121 

http://www.air-zone.com/

 

[email protected] 

 

All rights reserved   

Copyright Air-Zone Inc. 2012 

Summary of Contents for XT-400

Page 1: ... Ozone Generator Operating Instructions Air Zone Inc 1980 Northgate Commerce Parkway Suite 6C Suffolk VA 23435 757 465 1121 http www air zone com AirZoneAir aol com All rights reserved Copyright Air Zone Inc 2012 ...

Page 2: ...tructions 2 Contents XT 400 800 Ozone Generators 3 Controls 3 Half Power Control 5 Wireless Infrared Remote Control 5 Location of Unit 7 Ozone Levels 7 Shock Treatments 8 Maintenance 9 Warranty Information 10 Specifications 11 ...

Page 3: ...off ozone level timer and fan speed The four small lights surrounding the main Digital Display will show the different FUNCTIONS of the unit The proper light must be lit for the function to be controlled The lights represent Power P Ozone Level O3 Fan Speed F and the Countdown Timer T Press the FUNCTION button until just the P light and the light for the function to be controlled are lit The P lig...

Page 4: ...ll only come on for the seconds per minute assigned to the Ozone Level 5 To set the COUNTDOWN TIMER press the FUNCTION button until the TIMER T light and the Power P light are lit Push the up or down buttons at the left hand side to set the countdown timer for 10 20 30 40 50 60 up to 90 minutes The Timer can also be set to the cn level which means it will run continually and not shut off The unit ...

Page 5: ...itched off The bottom three elements are shut off and the total output of the machine then becomes 400mg hr If the XT 800 is too powerful for a given situation the half power mode can be chosen The Half Power button is the green button located on the rear of the unit The user can tell what mode the unit is in by looking at the elements lit up in the nose of the unit At full power all 6 elements ar...

Page 6: ... To Set the Ozone Level O3 Press the FUNCTION button until the green O3 light is lit Use the UP and DOWN buttons to set the ozone level up or down from level 1 to level 10 This will burst the ozone on for either 2 5 10 15 20 25 30 40 50 or 60 seconds per minute Level 10 is 60 seconds per minute or continuous The Power P light is steady red when ozone is being produced and blinks red while counting...

Page 7: ...ilding up around the occupants Firing the unit into the return air duct of an air handling system is an excellent way to assure even distribution of ozone throughout an entire house Ozone Levels Ozone at low levels has a fresh clean smell much like that of a rainstorm It is not necessary to smell the sweet smell of ozone for it to be effective Ozone works best when it is turned down below the leve...

Page 8: ...most effective air cleaning from ozone it is recommended that you use as little ozone as possible to control odors Shock Treatments If there are strong odors the room should be pre treated with a High Ozone Shock Treatment to remove the odor BEFORE attempting to run the machine at a lower air purification level of ozone To remove strong odors in a room the ozone level should be set to its highest ...

Page 9: ... PERFORMED IN ROOMS THAT ARE UNOCCUPIED OF ALL PEOPLE PLANTS OR ANIMALS Maintenance The model XT 400 800 ozone generators incorporate a patented method of corona discharge ozone generation that requires almost no maintenance ALWAYS unplug the unit before cleaning The outside of the unit can be cleaned with a moist paper towel A small vacuum attachment can be used to gently vacuum the dust that may...

Page 10: ...y purchase additional replacement filters from Air Zone Inc The corona elements inside may eventually burn out or become so dirty they will need to be replaced If you suspect the unit has a burnt out element turn the ozone level to its highest setting and turn the light out in the room If one of the elements is not glowing purple or is glowing very dimly then that element may need changing There a...

Page 11: ...s can be obtained from us by phone or email Air Zone is not responsible for any damages caused by the use or misuse of this unit Technical Specifications XT 400 Rated Ozone Output Per Hour Fully variable from 13 mg hr to 400 mg hr ACTUAL OZONE OUTPUT 445 mg hr ozone output verified by SGS Burst Timer 2 5 10 20 25 30 40 50 or 60 seconds per minute continuous Generation Method Corona Discharge US Pa...

Page 12: ...00 800 Operating Instructions 12 Air Zone Inc 1980 Northgate Commerce Parkway Suite 6C Suffolk VA 23435 757 465 1121 http www air zone com AirZoneAir aol com All rights reserved Copyright Air Zone Inc 2012 ...

Reviews: