Air OPUS
®
120V & 12V POWER SYSTEM
120V Shore Power Connection - Safe operating procedures
The OPUS® comes fitted with a 120 volt power system. This 120 Volt power system complies
with NFPA regulations.
The main circuit breaker and panel is located in the electrics cupboard accessibly externally
to the left of the door, behind the main cupboard center door on the driver’s side. Always
ensure you have a clear access to the cupboard door and it is not blocked at any time.
The Shore power hookup is located on the driver’s side at the front of the OPUS®. There are
three internal 120v power points.
•
Behind the main circuit board. This unit is designed to supply the battery charger.
•
In the storage next to the door
•
In the storage area behind the seating area next to the front bed.
www.opuscamper.us
17
T ENT INFLA
TION TECHNOLOGY
12V Power - Safe operating procedures
The OPUS® has many 12v outlets they are a combination of standard 12v sockets, mini 12v
sockets, USB sockets and switches.
You will find their location as follows:
•
In the front tool box / fridge compartment there is a standard 12v socket. In the same
area there is a small switch that operates the fan located in the door (if fitted on this
model)
•
On both sides of the tool box there is an LED work light. This has an automatic on/off
switch
•
Inside the OPUS® there are four 12v mini sockets. These are for the 12v LED lights at
the bed end. Above the main circuit board there is a twin 12v USB socket.
•
Externally at the rear passage side next to the kitchen slide-out there are two additional
12v mini sockets and a standard 12v socket. The two mini sockets are designed to
operate the 12v LED light on the kitchen and a small annex light.
12 Volt - Safe operating procedures
The Air OPUS
®
has many 12V outlets - they are a combination of standard 12V
sockets,12V light sockets, USB sockets and switches. These are located throughout
your camper trailer both internally and externally.
Next to the main door you will find your stereo system, light switch and dimmers for
internal and external fixed body lighting. The dimmers will only operate the build-in
lighting and will not influence any other lighting you run via sockets.
The control panel has a battery volt-meter that will provide an indication of the remaining
charge of the batteries and amp draw display in real time. A full battery will be indicated
by the Battery Level Indicator.
There are also two water tank gauges which will display the water level when pressed.
All switches have their own resetable fuse next to each of the switches in addition toa
master resetable circuit breaker for the whole 12V system located next to these controls.
Your batteries are also fused - in the battery compartment the large resettable fuse is
wired to the 7-pin wiring harness fitted at the drawbar.
All sockets, fridge power and lighting will operate on 12V power from the on board
batteries; heavy usage and power hungry appliances will deplete the battery’s charge.
It is recommended to have the mains 120V connected to a suitable supply if available,
even if appliances are run on 12V only, to ensure your batteries remain topped up.
The battery charger is fully automatic and will recharge the batteries if the
Air OPUS
®
is connected to an 120V electric power supply via the 30amp power inlet.
Do not unplug or disconnect this charger internally
as it may lose memory settings
for your battery set up and affect your charging. This is an automatic cycle charger and
if using, allow enough time for the charger to complete a full charge cycle.
Regular battery maintenance checks (charge once a month) will prolong the life of
your battery as AGM/Deep Cycle Batteries do not like to be drained flat.
Refer to your battery charger instruction manual for further details.
Air OPUS
®
12 VOLT POWER
18
www.opuscamper.us
T ENT INFLA
TION TECHNOLOGY
IMPORTANT
Your towing vehicle must have an in-car electric brake
controller installed or your warranty will be voided.
TOWING WIRING
The trailer lights and electric brakes are wired to a standard 7 pin trailer plug.
The
Air OPUS
®
is fitted with electric brakes. While in transit if the tow vehicle has the
7-pin connected this will also be topping up the batteries.