background image

6

en

PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!

Important safety instructions

•  Prior to using the appliance, read through the  

in structions for complete use and retain in a safe  

place for later reference.

•  WARNING – Only use the Ultrasonic indoors and within 

the specified technical data. Improper use can be  

hazardous for the health and lead to critical injury.

•  Connect the unit only to alternating current (AC) with  

voltage according to the rating label.

•  Children cannot recognize the hazards associated  

with the usage of electrical appliances. For this reason, 

always supervise children when they are near the  

humidifier (image 1).

•  Never use the appliance if there is any damage to the 

appliance or cable (2), after malfunction, after the  

appliance has been dropped (3) or damaged in any 

other way.

•  Repairs of electrical appliances are only to be made by 

qualified service engineers (4). Improper repair work 

can cause considerable danger to the user.

•  Place the humidifier on a dry, level surface (5). 

• 

Do not place the appliance directly on the floor

 or 

next to a heating vent (6). 

•  If the mist comes in contact with the floor prior to  

evaporating, the floor surface can become damaged. 

We do not accept any liability for damages in the case 

of incorrect placement of the unit.

•  The unit should be placed in an elevated position (7),  

e.g. on a table, chest of drawers, etc.

•  Place appliance where it is not easily knocked over (8).

•  Always unplug when not in use.

•  Only operate the humidifier when it is completely  

assembled.

•  ALWAYS unplug before removing/filling/emptying the 

water tank, before cleaning/maintaining, assembling/

dismantling of individual parts and before moving the 

appliance.

•  Do not touch the water in the base during operation  

because of high frequency vibrations in the water.

•  Do not run power cords under carpets, and do not  

cover with throw rugs. Arrange cord so that it will not 

be tripped over.

•  Never pull the plug from the outlet by the cable or with 

wet hands.

•  Do not use the appliance where combustible gases or 

vapors are present.

•  Do not expose the appliance to rain, or use near water, 

in a bathroom, laundry area or other damp location.

•  This unit must be used in its upright position.

•  Do not allow foreign objects to enter ventilation or 

ex haust opening as this may cause electric shock or 

damage to the appliance. Do not block air outlets or 

intakes.

•  Do not pour water into the mist outlet of the appliance.

•  This appliance has a polarized plug (one blade is wider 

than the other). To reduce risk of shock, this plug is 

intended to fit in a polarized outlet only one way. If the 

plug does not fit fully in the outlet, reverse the plug. If it 

still does not fit, contact a qualified electrician. DO NOT 

attempt to defeat this safety feature.

•  A loose fit between the plug (receptacle) and the  

AC outlet may cause overheating and a distortion  

of the plug. Contact a qualified electrician to replace 

loose or worn receptacles.

•  Do not sit, stand or place any heavy objects on the 

appliance.

•  Do not submerge the main body in water or other 

liquids.

•  Disconnect power supply before servicing.

•  Persons who are not familiar with the instructions  

for use, as well as children and persons under the  

influence of medication, alcohol, or drugs are not  

permitted to operate the appliance, or are only  

per mitted to operate it under supervision.

•  To protect 

health safety

 and 

proper humidifier

 function 

use only clean, contamination-free, cold, fresh tap wa-

ter in your humidifier. If your water source is contam- 

inated or if you are uncertain of its safety use distilled 

water. In addition, it is advised to 

clean and maintain 

your humidifier

 in a timely manner 

as instructed in 

this manual.

•  The use of water additives, such as ethereal/essential 

oils, fragrances, eucalyptus, water conditioners etc., 

damages the tank material and as a consequence 

the whole unit. Any use of such additives will void the 

manufacturer’s warranty.

•  Remark: Neither humans nor animals can hear the high 

frequency vibrations.

Summary of Contents for AOS U650

Page 1: ...TIONS LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS POR FAVOR LEA Y GUARDE TODAS LAS INSTRUCCIONES AOS 7145 7147 Service Questions Contact Air O Swiss at 800 336 0326 Sales Inquiries Contact Sylvane at 8...

Page 2: ......

Page 3: ...3 Instructions for use 5 22 en Instructions d utilisation 23 40 a fr Instrucciones para el uso 41 57 a es...

Page 4: ...4...

Page 5: ...5 en Instructions for use...

Page 6: ...over Never pull the plug from the outlet by the cable or with wet hands Do not use the appliance where combustible gases or vapors are present Do not expose the appliance to rain or use near water in...

Page 7: ...7 en 5 1 3 7 9 6 2 4 8...

Page 8: ...ral information A comfortable atmosphere indoors is reached with a rela tive humidity level between 40 and 60 Your humidifier automatically controls the humidity level according to the desired setting...

Page 9: ...tion of the appliance Mist outlet rotating Evaporation chamber Water tank Demineralization cartridge Main body Control panel Water tank cap Hydro Stick Power Plug Membrane Brush Nebulizer space Water...

Page 10: ...exchange the water and empty the water from the base before using the humidifier On average the demineralization cartridge should be replaced every 2 3 months depending on your water hardness Some ar...

Page 11: ...14 Make sure that no foreign objects are in the water tank Fill the tank with clean cold water from the tap 15 Close the cap of the water tank securely place the wa ter tank onto the base 16 The wate...

Page 12: ...vertical position The accu racy of measurement is 5 The unit will switch off when the moisture level exceeds the desired setting The appliance does not switch off if the switch is turned all the way t...

Page 13: ...perature does not drop and in addition it significantly improves the water quality maintenance F Automatic mode and Sleep mode The automatic and sleep modes can be activated by pres sing button F By p...

Page 14: ...cket for 32 oz of water Do not change the ratio Do NOT run the unit when using EZCal This can cause damage to the product and voids the warranty Thoroughly rinse the base with tap water after using EZ...

Page 15: ...midifier s functionality while providing fresh humidification performance It starts to work as soon as it comes in to contact with water even if the unit is turned off The Hydro Stick should be change...

Page 16: ...nk cap 44 Close tank cap well and place the tank on the main body 45 Replacement of the demineralization cartridge Always unplug the unit before removing the water tank Do not touch the water in the b...

Page 17: ...17 en 44 34 35 36 37 38 39 41 43 40 42 45...

Page 18: ...ption up to 40 W 125 W Humidity output up to 3 5 gallons 24 h Suitable for rooms up to 650 sq ft 60 m2 Dimensions LxWxH 9 5 x 10 3 x 12 2 in 24 x 26 x 31 cm Weight empty 6 6 lbs 3 kg Accessories AOS 7...

Page 19: ...ge cap A Those directions are there in case you decide to use the refill option to replace the granules the purpose is for how to open and close the cap If you did open the cap before placing it in th...

Page 20: ...as an influence on the humidity Reasons for low humidity level air circulation is very high air is fully exchanged se veral times per day the humidifier needs to starts its work from scratch insulatio...

Page 21: ...heir highest level between recommended cleanings Good for one year the Hydro Stick ensures the humidifier s functionality while providing fresh humidification performance It needs to be replaced once...

Page 22: ...22 en...

Page 23: ...Please check our website www airoswiss net for further information AIR O SWISS is a registered trademark of PLASTON Group Switzerland 36484 01...

Reviews: