•  Turn the plastic cup and cartridge over and shake until 

all granules are in the cartridge (37).

•  Remove the plastic cup and the pink styrofoam piece 

from the cartridge (38) and retain for future use (the 

refill granules consists of 3 refill bags) (39).

•  Close the cartridge (40).

•  Soak the demineralization cartridge in a water bath 

  24 hours before using it (43). The granules have to 

absorb water to reach maximum performance. If the 

cartridge is soaked in the tank, make sure to exchange 

the water and empty the water from the base before 

using the humidifier.

•  Screw the cartridge on the water tank cap (44).

•  Screw the cartridge on the bottom side of the water 

tank, put the tank on the main body (45).

Placing granules in the center of the cartridge 

allows them to escape in the unit or to clog the 

unit. The unit will no longer operate properly and 

the granules need to be cleaned out thoroughly.

Option B: replace the whole cartridge

•  Remove the water tank from the base and unscrew the 

water tank cap (30).

•  The demineralization cartridge is attached to the tank 

cap. Unscrew the cartridge from the cap by turning it 

counter-clockwise (31). Important: do NOT dispose of 

the water tank cap!

•  Throw the whole cartridge into the waste (41).

•  Unpack the new cartridge (42). 

•  Soak the demineralization cartridge in a water bath  

24 hours before using it (43). The granules have to 

absorb water to reach maximum performance. If the 

cartridge is soaked in the tank, make sure to exchange 

the water and empty the water from the base before 

using the humidifier.

•  Screw the cartridge on the water tank cap (44). Close 

tank cap well and place the tank on the main body 

(45).

Replacement of the demineralization  

cartridge

Always  unplug  the  unit  before  removing  the 

water tank. Do not touch the water in the base 

during operation!

The  water  tank  is  equipped  with  a  demineralization  cart-

ridge. This cartridge has to be replaced every 2 – 3 months. 

If the water is very hard, it may be necessary to replace the 

cartridge earlier. White dust around the device is a sure sign 

that the cartridge needs replacing. If white residue still forms 

around the device after a new cartridge has been inserted, 

please make sure that the water you are using is untreated. 

If the water flows through a decalcification system – such as 

an ion exchanger – (sodium is added to remove calcium) in 

the building before it is used in the humidifier, salt can pre- 

cipitate as white dust around the device. The demineralization 

cartridge or the granules must be exchanged at the latest 

after 6 months or the unit does not reach its full performance 

anymore.

Option A: replace the granules

•  Remove the water tank from the base and unscrew the 

water tank cap (30).

•  The demineralization cartridge is attached to the tank 

cap. Unscrew the cartridge from the cap by turning it 

counter-clockwise (31). Important: do NOT dispose of 

the water tank cap!

•  Open the cartridge (32).

•  Throw the content into the waste (Attention! Disposed 

granules can make the floor slippery!) (33).

•  Place the enclosed pink styrofoam piece in the center 

of the cartridge. Do not push it to the bottom as it will 

be difficult to remove afterwards (34).

•  Pour the contents of one refill granules bag into the 

plastic cup that is included with the refill granules pa-

ckaging (35).

•  Place the empty cartridge with the plug in the center 

onto the plastic cup (36).

32

33

Summary of Contents for AOS U650

Page 1: ...TIONS LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS POR FAVOR LEA Y GUARDE TODAS LAS INSTRUCCIONES AOS 7145 7147 Service Questions Contact Air O Swiss at 800 336 0326 Sales Inquiries Contact Sylvane at 8...

Page 2: ......

Page 3: ...3 Instructions for use 5 22 en Instructions d utilisation 23 40 a fr Instrucciones para el uso 41 57 a es...

Page 4: ...4...

Page 5: ...5 en Instructions for use...

Page 6: ...over Never pull the plug from the outlet by the cable or with wet hands Do not use the appliance where combustible gases or vapors are present Do not expose the appliance to rain or use near water in...

Page 7: ...7 en 5 1 3 7 9 6 2 4 8...

Page 8: ...ral information A comfortable atmosphere indoors is reached with a rela tive humidity level between 40 and 60 Your humidifier automatically controls the humidity level according to the desired setting...

Page 9: ...tion of the appliance Mist outlet rotating Evaporation chamber Water tank Demineralization cartridge Main body Control panel Water tank cap Hydro Stick Power Plug Membrane Brush Nebulizer space Water...

Page 10: ...exchange the water and empty the water from the base before using the humidifier On average the demineralization cartridge should be replaced every 2 3 months depending on your water hardness Some ar...

Page 11: ...14 Make sure that no foreign objects are in the water tank Fill the tank with clean cold water from the tap 15 Close the cap of the water tank securely place the wa ter tank onto the base 16 The wate...

Page 12: ...vertical position The accu racy of measurement is 5 The unit will switch off when the moisture level exceeds the desired setting The appliance does not switch off if the switch is turned all the way t...

Page 13: ...perature does not drop and in addition it significantly improves the water quality maintenance F Automatic mode and Sleep mode The automatic and sleep modes can be activated by pres sing button F By p...

Page 14: ...cket for 32 oz of water Do not change the ratio Do NOT run the unit when using EZCal This can cause damage to the product and voids the warranty Thoroughly rinse the base with tap water after using EZ...

Page 15: ...midifier s functionality while providing fresh humidification performance It starts to work as soon as it comes in to contact with water even if the unit is turned off The Hydro Stick should be change...

Page 16: ...nk cap 44 Close tank cap well and place the tank on the main body 45 Replacement of the demineralization cartridge Always unplug the unit before removing the water tank Do not touch the water in the b...

Page 17: ...17 en 44 34 35 36 37 38 39 41 43 40 42 45...

Page 18: ...ption up to 40 W 125 W Humidity output up to 3 5 gallons 24 h Suitable for rooms up to 650 sq ft 60 m2 Dimensions LxWxH 9 5 x 10 3 x 12 2 in 24 x 26 x 31 cm Weight empty 6 6 lbs 3 kg Accessories AOS 7...

Page 19: ...ge cap A Those directions are there in case you decide to use the refill option to replace the granules the purpose is for how to open and close the cap If you did open the cap before placing it in th...

Page 20: ...as an influence on the humidity Reasons for low humidity level air circulation is very high air is fully exchanged se veral times per day the humidifier needs to starts its work from scratch insulatio...

Page 21: ...heir highest level between recommended cleanings Good for one year the Hydro Stick ensures the humidifier s functionality while providing fresh humidification performance It needs to be replaced once...

Page 22: ...22 en...

Page 23: ...Please check our website www airoswiss net for further information AIR O SWISS is a registered trademark of PLASTON Group Switzerland 36484 01...

Reviews: