background image

10

en

Setting up

Finding the ideal location for your unit:

•  Do not place the humidifier directly next to a heating 

vent or on a floor with floor heating. The moisture of 

the mist can damage the floor surface (6) (see Safety 

Instructions).

•  The unit should be placed in an elevated position (7),  

e.g. on a table, chest, etc. at least 3 ft off the floor.

•  The mist outlet must not be pointed directly at  

plants, furniture, or other objects (12). Keep distance of 

at least 20 inches (50cm).

•  Soak the demineralization cartridge in a water bath 

24 hours before using it (13). The granules have to 

absorb water to reach maximum performance. If the 

cartridge is soaked in the tank, make sure to exchange 

the water and empty the water from the base before 

using the humidifier. 

•  On average the demineralization cartridge should be 

replaced every 2 – 3 months depending on your water 

hardness. Some areas may need to replace the cart-

ridge sooner, some may last longer. The cartridge must 

be exchanged at the latest after 6 months or the unit 

does not reach its full performance anymore.

   See «Replacement of the demineralization cartridge».

•  Read the instructions under «Filling the Tank» for  

adding water in the humidifier (14 and 15).

•  Place the water tank onto the base.

•  Insert the plug into the socket and switch on the  

appliance using the on/off dial (18 and 19).

•  About 10 to 15 minutes after it is switched on the de-

vice will reach its full output level.

•  Make sure that the cable is not pinched anywhere (9). 

Do not operate the humidifier if the cable is damaged 

(2).

12

13

Summary of Contents for AOS U650

Page 1: ...TIONS LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS POR FAVOR LEA Y GUARDE TODAS LAS INSTRUCCIONES AOS 7145 7147 Service Questions Contact Air O Swiss at 800 336 0326 Sales Inquiries Contact Sylvane at 8...

Page 2: ......

Page 3: ...3 Instructions for use 5 22 en Instructions d utilisation 23 40 a fr Instrucciones para el uso 41 57 a es...

Page 4: ...4...

Page 5: ...5 en Instructions for use...

Page 6: ...over Never pull the plug from the outlet by the cable or with wet hands Do not use the appliance where combustible gases or vapors are present Do not expose the appliance to rain or use near water in...

Page 7: ...7 en 5 1 3 7 9 6 2 4 8...

Page 8: ...ral information A comfortable atmosphere indoors is reached with a rela tive humidity level between 40 and 60 Your humidifier automatically controls the humidity level according to the desired setting...

Page 9: ...tion of the appliance Mist outlet rotating Evaporation chamber Water tank Demineralization cartridge Main body Control panel Water tank cap Hydro Stick Power Plug Membrane Brush Nebulizer space Water...

Page 10: ...exchange the water and empty the water from the base before using the humidifier On average the demineralization cartridge should be replaced every 2 3 months depending on your water hardness Some ar...

Page 11: ...14 Make sure that no foreign objects are in the water tank Fill the tank with clean cold water from the tap 15 Close the cap of the water tank securely place the wa ter tank onto the base 16 The wate...

Page 12: ...vertical position The accu racy of measurement is 5 The unit will switch off when the moisture level exceeds the desired setting The appliance does not switch off if the switch is turned all the way t...

Page 13: ...perature does not drop and in addition it significantly improves the water quality maintenance F Automatic mode and Sleep mode The automatic and sleep modes can be activated by pres sing button F By p...

Page 14: ...cket for 32 oz of water Do not change the ratio Do NOT run the unit when using EZCal This can cause damage to the product and voids the warranty Thoroughly rinse the base with tap water after using EZ...

Page 15: ...midifier s functionality while providing fresh humidification performance It starts to work as soon as it comes in to contact with water even if the unit is turned off The Hydro Stick should be change...

Page 16: ...nk cap 44 Close tank cap well and place the tank on the main body 45 Replacement of the demineralization cartridge Always unplug the unit before removing the water tank Do not touch the water in the b...

Page 17: ...17 en 44 34 35 36 37 38 39 41 43 40 42 45...

Page 18: ...ption up to 40 W 125 W Humidity output up to 3 5 gallons 24 h Suitable for rooms up to 650 sq ft 60 m2 Dimensions LxWxH 9 5 x 10 3 x 12 2 in 24 x 26 x 31 cm Weight empty 6 6 lbs 3 kg Accessories AOS 7...

Page 19: ...ge cap A Those directions are there in case you decide to use the refill option to replace the granules the purpose is for how to open and close the cap If you did open the cap before placing it in th...

Page 20: ...as an influence on the humidity Reasons for low humidity level air circulation is very high air is fully exchanged se veral times per day the humidifier needs to starts its work from scratch insulatio...

Page 21: ...heir highest level between recommended cleanings Good for one year the Hydro Stick ensures the humidifier s functionality while providing fresh humidification performance It needs to be replaced once...

Page 22: ...22 en...

Page 23: ...Please check our website www airoswiss net for further information AIR O SWISS is a registered trademark of PLASTON Group Switzerland 36484 01...