Filling the tank

Always unplug the unit before removing the water tank. Do 

not operate the appliance when the water tank is empty! 

Only fill the water tank with fresh, cold tap wa­

ter. Use water additives at your own risk. We do 

no accept any liability for possible reductions in 

performance or damage. 

Do not put the water tank under pressure, e.g. by filling with 

carbonated mineral water. Do not add any essential oils or 

fragrances to the water; the plastic material might become 

discolored and damaged. Close cap tightly (19) to prevent 

water from leaking out of the tank.

•  Remove the water tank (16).

•  Ensure that there are no foreign objects in the water 

tank.

•  Remove the water tank cap from the tank (17). Fill the 

tank with fresh, cold tap water (18). Fully close the 

water tank cap to prevent the water tank from leaking 

(19). Place the water tank on the water base (20). 

•  After filling the water tank, most of the water will 

empty into the base. The water tank may be filled a 

second time (base will not overflow).

•  Connect the cable to the outlet and switch the ap­ 

pliance on.

•  The red empty indicator light may stay illuminated for 

some seconds until the base is filled with water.

The unit is fitted with an automatic cut­off switch. As soon 

as the water tank is empty, the unit switches off automa­

tically;  the  empty  indicator  illuminates  (also  see  section 

«Operating 2055A»).

Use of fragrances

The  base  contains  a  special  fragrance  container  (21). A 

cotton  ball  soaked  with  fragrance  can  be  placed  in  this 

container. Place fragrances only in the container provided! 

Do not pour fragrances in fragrance container directly! Use 

with cotton ball only. Water additives (e.g. essential oils, fra­

grances, water conditioners) must NOT be used in the tank 

or anywhere else in the appliance! Even a small amount 

can damage the plastic or cause cracks. The material is 

not suitable for the use of additives. One drop is enough 

to damage the water tank and therefore render the unit 

unusable. Appliances  that  are  damaged  by  additives  are 

excluded from the warranty. The fragrance container is also 

used as a tool for opening the rotary locks of the humi­

difying discs. To learn more about removing the discs, refer 

to section «Cleaning the humidifying discs». 

19

16

18

17

20

21

Summary of Contents for AOS 2055A

Page 1: ...AOS 2055A PLEASE READ AND SAVE ALL INSTRUCTIONS LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS POR FAVOR LEA Y GUARDE TODAS LAS INSTRUCCIONES...

Page 2: ......

Page 3: ...3 Instructions for use 5 18 en Instructions d utilisation 19 32 a fr Instrucciones para el uso 33 46 a es...

Page 4: ...4...

Page 5: ...5 en Instructions for use...

Page 6: ...the cable or with wet hands 7 Do not use the appliance where combustible gases or vapors are present Do not expose the appliance to rain or use near water in a bathroom laundry area or other damp loc...

Page 7: ...7 en 5 1 3 7 9 6 2 4 8...

Page 8: ...ge cleansing capacity through pre ionization The individual dust particles are ionized charged and stick to the humidifier discs 10 11 12 Special humidifying discs rotate in a water bath inside the un...

Page 9: ...oor or on a level dry surface in the room Pay proper attention to easy accessibility and sufficient space for servicing and cleaning the unit Read the section Filling the tank on how to fill the water...

Page 10: ...le to the outlet and switch the ap pliance on The red empty indicator light may stay illuminated for some seconds until the base is filled with water The unit is fitted with an automatic cut off switc...

Page 11: ...g When lifting the upper part off the housing the appliance also switches off In this case the red light E will also appear on the display Only when the upper part is replaced on the base does the red...

Page 12: ...aning the fan The cover can be removed from the upper part of the unit 31 Under this cover is the fan 32 which can be cleaned with a damp cleaning cloth as required Water quality maintenance The AIR O...

Page 13: ...13 en ACID 2 1 3 24 28 25 31 29 26 30 32 27...

Page 14: ...the base with tap water after using EZCal and make sure no EZCal resi dues remain in the base Empty the water base 38 remove the disc assembly 39 and rinse 40 Remove deposits from the base using a pla...

Page 15: ...15 en 30 min 140 F 60 C 37 38 39 41 40 42 43 44 45...

Page 16: ...wiss net Technical specifications Electrical voltage 120 V 60 Hz Power consumption 29 W Humidity output up to 3 gallons 24h Suitable for rooms up to 600 sq ft 55 m2 Dimensions 14 2 x 14 2 x 14 2 in 36...

Page 17: ...humidity is lower Relative humidity means the amount of water vapor in the air compared to the amount the air could hold if it was totally saturated The difference is higher between outside and inside...

Page 18: ...he air could hold if it was totally saturated position of the unit if it is placed close to a door win dow or air vent This increases the air circulation Q Can this unit be used all year round A Yes t...

Page 19: ...Please check our website www airoswiss net for further information AIR O SWISS is a registered trademark of PLASTON Group Switzerland 36130 01...

Reviews: