![Air Live FE-200VD User Manual Download Page 10](http://html.mh-extra.com/html/air-live/fe-200vd/fe-200vd_user-manual_2875201010.webp)
1. Introduction
AirLive FE-200VD Manual
4
2. DI/DO connector:
DI/ DO: Connect to sensor in and alarm out devices
Pin Function Description
1 COM
2 RELAY-NO
Digital output implementation; Pin2 to COM (Pin1) is a
Photo-coupled relay on Normal Open status. External device can
directly connect to the terminals. However the current that will go
through the 2 nodes must not exceed 130mA. An external “Relay”
can also be connected to the terminals as an implementation. In
this case, current (or/and voltage) limitation is specified by the
external Relay.
3 GND
4 DIGITAL-IN
Connect to GND to activate, or leave floating (or unconnected) to
deactivate.
5 GND
6 DEFAULT
PIN with a short wire connecting two revert to factory default
settings.
3. Factory Default Reset
To restore factory default, please follow the steps:
1.
Unplug the power jack to turn off the camera
2.
Short pin 5 and pin 6 with a wire
3.
Plug in the power jack to turn on the camera. The power LED will start flashing
in a short while.
4.
Break the short when the LED starts quick flashing. Wait for a few minutes the
device should be set back to factory default.
Note:
Restoring the factory default setting will lose the all previous settings included IP
address forever. A user needs to run the IPWizard II program to search the device and
configure it to let the device work properly again.
4. DC-in Jack
The input power is 12VDC.
Note:
Please use the bundle adapter for the Network Camera. Otherwise, the product
may be damaged.
5. MIC in (audio in)
Connect a microphone to the network camera.