Always protect the pressure regulator 
from damage (visual inspection at regular 
intervals).

  

The factory settings of the connection 
seals must not be changed.

5.2

   Ensure that the connector seals, sealing  

surfaces and gauges are in perfect con-
dition.

 

 

If a fault occurs, for example if the 

 

outlet pressure rises when output = 0,  
if there are leaks into the atmosphere, 
the guages are defective, or when the 
safety valve is activated, shut off the 
pressure regulator , close the cylinder 
valve immediately.

Air Liquide recommends annual periodic in-
spections of the pressure regulator by compe-
tent, authorized personnel.

  Faults that occur can have many causes. 

For your own safety, avoid tampering or 
making repairs on your own.

6 Repairs

  

Repairs to the pressure regulators must 
only be done by competent and trained 
personnel in authorized specialist work-
shops. Only original spare parts must be 
used for repairs.

6.1

 

  If unauthorized repairs or changes are 
made by the user or a third party without 
permission from the manufacturer, then li-
ability for the consequences is rescinded.

7   

Cylinder pressure regula-

tors with flow meter gauge

For these pressure regulators, points 1 to 7 
in this operating manual also apply. The flow 
quantity set by the pressure adjustment screw 
(5) is indicated on the flow meter gauge (4). In 
pressure regulators with a flow meter gauge, a 
regulating office/ throttle (for pressure control) 
(9) is built in. Check if a regulating office/ throt-
tle (for pressure control) is already installed in 
your equipment. If yes this must be removed 
because the mounting holes are not adapted to 
the pressure regulator.

8   Indications to Cylinder 

pressure regulator having 

Flowmeter

Setting of the required flow:
1. 

 Close shut-off valve (6)

2. 

 Open slowly cylinder valve (1). 

 

 The inlet gauge (3) is indicating the cylin-
der pressure.

3. 

 Open shut-off valve (6) and correspond-
ing shut-off valve of the implement.

4. 

 Set the desired flow by adjustment valve 
(6).

9 Guarantee

The standard warranty period is one year from 
the date of delivery in accordance with the 
general terms and conditions of Air Liquide 
Deutschland GmbH, Air Liquide Austria GmbH 
and Carbagas AG. The standard warranty pe-
riod is only valid for goods that have been used 
according to the operating manual and general-
ly applicable industry practices and standards.

10 Note

Please use the product only for the purpose 
that Air Liquide intended and only if you are 
competent in the application and follow the 
technical safety guidelines or safety proce-
dures. If there are any doubts related to the 
use of the product, request specific Air Liquide 
product information beforehand or talk to an Air 
Liquide specialist.