Air Liquide PRIMEJET User Manual Download Page 3

1 Use

1.1  Intended use

These cylinder pressure regulators are intend-
ed for use with compressed gases released 
under pressure, on pressurized gas cylinders 
up to 300 bar filling pressure (depending on 
technical design) as well as for liquid gases, 
to reduce the corresponding cylinder pressure 
and to keep the desired working pressure con-
stant. The pressure regulator must only be used 
for gases for which a symbol is present on the 
pressure regulator (see symbols Point 3).

1.2  Unintended use

• 

 Pressure regulation valves must not be 
used for liquids

•  

 Pressure regulators must not be operat-
ed in ambient temperatures below -20 °C 
and above 60 °C

•  

 Do not use pressure regulators for ag-
gressive gases such as ethylamine, dieth-
ylamine, ammonia etc.

1.3   Directive  97/23/EC:   

Pressurised equipment (PED)

AIR LIQUIDE equipment of DN 

25 mm 

(e.g. pressure regulators, valves, non return 
valves

) satisfy to requirement of article 3§3 

of 97/23/EC directive and at the state of 
the art. Consequently, these equipments shall 
not be CE marked as defined in article 15. 
By design, these equipment may inte-
grate pressure relief valves or burst disks. 
In this case, those ones shall neither be CE 
marked according to paragraph 2 of annex II. 
In other case, pressure relief valves and burst 
disks shall be CE Marked.

2  Safety instructions

  

All indications labeled with this symbol 
are considered as special safety instruc-
tions.

2.1

   The pressure regulators conform to the 

recognized state of the art, as well as the  
requirements of existing standards.

 

 No changes or alterations may be per-
formed without the manufacturer‘s per-
mission.

2.2

   No adapters should be installed between 

the cylinder valve and the cylinder pres-
sure regulator.

 

 Improper operation, or use for purposes 
other than those intended can create 
hazards for the user and other persons, 
as well as damage to the pressure regu-
lator.

2.3

   

Regulations that are applicable in 
Germany:

2.3.1

   Accident prevention regulations / 

 

DGUV rules

• 

100-001 “Principles of prevention“

• 

 

113-001 

“Explosion prevention rules“ 

Name plate

• 

100-500 “Operation of work equipment“

2.3.2

 Laws, directives, technical regulations

 

 

Product safety law (ProdSG) with the 

 

specific:

•  

Product safety directives (ProdSV), 

 

e.g. Explosion protection directive (11. ProdSV) 
or Pressure device directive (14. ProdSV)  
5. Dimensional drawing

• 

Work safety directive with Appendix  1 – 3

• 

Work safety technical rules  (TRBS)

• 

 

Hazardous materials technical rules 

 

(TRGS)

• 

Plant safety technical rules (TRAS)

2.3.3

  Bulletins, norms and guidelines

• 

Pressure equipment directive, 2014/68/EU

• 

 Bulletin Use of compressed gas cylinders 
(DVS 0212)

• 

 Refer to the safety data sheets of each  
specific gas type

2.4

  Regulations that are applicable in Austria:

• 

Employee protection law ASchG

Reviews: