ELECTRICAL REQUIREMENTS
Model K52 Vacuum only
A. 120 Volts AC Current
B. 20 AMPS Circuit Breaker
C. 60 HZ Single Phase
Model K52-9 Vacuum with Remote Air Solenoid
A. 120 Volts AC Current
B. 20 AMPS Circuit Breaker
C. 60 HZ Single Phase
Model K552-
Vacuum with ¾ H.P. Compressor
A. 120 Volts AC Current
B. 40 AMPS Circuit Breaker
C. 60 HZ Single Phase
The use of the recommended wire size is required for proper operation of all models. See
wire size guide below. If using aluminum wire increase gauge on size.
Building
Vacuum Machine
Run
Air King Model
#
Copper Wire Size
0 to 25 Ft
0 to 50 Ft
0 to 100 Ft
0 to 150 Ft
0 to 200 Ft
K52
K52-9
K552
14 GA
14 GA
8 GA
12 GA
12 GA
8 GA
10 GA
10 GA
6 GA
8 GA
8 GA
4 GA
6 GA
6 GA
4 GA
Note: The run should be the length from the circuit
Breaker inside the building to the Air/Vac. machine
outside the building.