background image

www.airkinglimited.com

A210572215 Rev. D 8-12

5 of 12

Troubleshooting Guide

    Trouble 

 

Probable Cause 

 

Suggested Remedy

  1.  Fan does not operate when the switch is on. 

1a.  A fuse may be blown or a circuit tripped. 

1a.  Replace fuse or reset circuit breaker.

     

1b.  Connector plug from motor is not plugged in.  1b.  Turn off power to unit. Remove Grill and plug motor into receptacle

     

 

 

 

in housing. Restore power to unit.

     

1c.  Wiring is not connected properly. 

1c.  Turn off power to unit. Check that all wires are connected.

     

1d 

Motor has stopped operating. 

1d.  Replace motor.

  2.  Fan is operating, but air moves slower than normal. 

2. 

Obstruction in the exhaust ducting. 

2. 

Check for any obstructions in the ducting. The most common are bird

     

 

 

 

nests in the roof cap or wall cap where the fan exhausts to the outside.

  3.  Fan is operating louder than normal 

3a.  Motor is loose. 

3a.  Turn off power to unit. Remove grill and check that all screws are fully

     

 

 

 

tightened. Restore power to unit.

     

3b.  Fan blade is hitting housing of unit. 

3b.  Call your dealer for service.

Installer: 

 

Installation Date: 

Place of Purchase: 

 

Model Number: 

LIMITED WARRANTY

WHAT THIS WARRANTY COVERS:

 This product is warranted against defects in workmanship and/or materials. 

HOW LONG THIS WARRANTY LASTS:

 This warranty extends only to the original purchaser of the product and lasts for five (5) years from the date of original purchase 

or until the original purchaser of the product sells or transfers the product, whichever first occurs. 

WHAT AIR KING WILL DO:

 During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole 

product with the same or comparable model. 

WHAT THIS WARRANTY DOES NOT COVER:

 This warranty does not apply if the product was damaged or failed because of accident, improper handling or operation, 

shipping damage, abuse, misuse, unauthorized repairs made or attempted. This warranty does not cover shipping costs for the return of products to Air King for repair or 

replacement. Air King will pay return shipping charges from Air King following warranty repairs or replacement 

ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY), LAST ONE YEAR 

FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT, WHICHEVER FIRST 

OCCURS AND IN NO EVENT SHALL AIR KING’S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES 

FROM ANY CAUSE WHATSOEVER, OR (II) REPLACMENT OR REPAIR OF ANY HOUSE FUSES, CIRCUIT BREAKERS OR RECEPTACLES. NOTWITHSTANDING ANYTHING TO 

THE CONTRARY, IN NO EVENT SHALL AIR KING’S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT 

AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.

Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so these 

exclusions or limitations may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state to state and province to 

province. Proof of purchase is required before a warranty claim will be accepted. 

CUSTOMER SERVICE:

Toll-Free (800) 465-7300

Our Customer Service team is available to assist you with product questions, service center locations, and replacement parts. They can be reached Monday through 

Friday, 8am-4pm Eastern. Please have your model number available, as well as the type and style (located on the label inside of your product). 

Please do not return product to place of purchase.

www.airkinglimited.com

PARTS FOR DISCONTINUED, OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE. DUE TO SAFETY REASONS, MANY ELECTRONIC COMPONENTS 

AND MOST HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT.

SECTION 8

Use and Care

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT SERVICE 

PANEL BEFORE SERVICING THE UNIT.

1. 

Cleaning the Grill:

 Remove grill and use a mild detergent, such 

as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY 

ABRASIVE PADS OR SCOURING POWDERS. Completely dry grill 

before reinstalling. Refer to instructions in 

Section 5

 

Finishing the 

Installation

, to reinstall grill.

2. 

Cleaning the Fan Assembly:

 Wipe all parts with a dry cloth or gently 

vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER.

Summary of Contents for ES130DG

Page 1: ...t be done by qualified person s in accordance with all applicable codes and standards including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases throu...

Page 2: ...ing material Figure 3 Set housing aside and cut opening being careful not to cut or damage any electrical or other hidden utilities Install the rails into the mounting channel on the housing Center th...

Page 3: ...com A210572215 Rev D 8 12 3 of 12 3b Intermittent Ventilation For two speed fans wired for intermittent ventilation with a standard duplex toggle switch such as Leviton 5224 2W not included Connect t...

Page 4: ...fan s grill and press the button 2 times The LED on the sensor will then flash the number of times to indicate the current setting this will repeat 3 times 1 time 30 seconds 2 times 2 5 minutes 6 tim...

Page 5: ...LL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY LAST ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT...

Page 6: ...REPLACEMENT PARTS DIAGRAM Qty Description Replacement Part 14 1 18 ga Ground Wire 5S1999111 15 1 Wire Compartment Assembly ES80SG 5S1239016 1 Wire Compartment Assembly ES130SG 5S1239017 16 1 Wire Com...

Page 7: ...en conformit avec tous les codes et normes applicables incluant la construction relative aux incendies b De l air en quantit suffisante est requis pour la bonne combustion et l vacuation de gaz par l...

Page 8: ...ention de ne pas couper ou endommager les installations lectriques ou d autres utilit s masqu es Installez les rails dans le canal de montage sur le bo tier Centrez le canal de montage dans les fentes...

Page 9: ...ses c bl s pour la ventilation intermittente avec un interrupteur bascule duplex standard tel que Leviton 5224 2W non inclus Reliez le fil blanc du ventilateur au fil neutre blanc de la source d alime...

Page 10: ...gril du ventilateur et appuyez sur le bouton 2 fois Le LED sur le capteur clignotera alors le nombre de fois pour indiquer le r glage actuel Ceci sera r p t 3 fois 1 fois 30 secondes 2 fois 2 5 minut...

Page 11: ...ntie Air King son choix r parera ou remplacera n importe quelle partie ou pi ces qui s av rent d fectueuses ou remplacera le produit entier par le m me mod le ou un mod le comparable CE QUE CETTE GARA...

Page 12: ...RAMME DES PI CES DE REMPLACEMENT de pi ce Qt Description de remplacement 14 1 Fil de mise la terre de calibre 18 5S1999111 15 1 Assembl e du compartiment du fil ES80SG 5S1239016 1 Assembl e du compart...

Reviews: